CVE-2020-8597 – ppp: Buffer overflow in the eap_request and eap_response functions in eap.c
https://notcve.org/view.php?id=CVE-2020-8597
eap.c in pppd in ppp 2.4.2 through 2.4.8 has an rhostname buffer overflow in the eap_request and eap_response functions. El archivo eap.c en pppd en ppp versiones 2.4.2 hasta 2.4.8, presenta un desbordamiento del búfer de rhostname en las funciones eap_request y eap_response. A buffer overflow flaw was found in the ppp package in versions 2.4.2 through 2.4.8. The bounds check for the rhostname was improperly constructed in the EAP request and response functions which could allow a buffer overflow to occur. Data confidentiality and integrity, as well as system availability, are all at risk with this vulnerability. • https://github.com/dointisme/CVE-2020-8597 https://github.com/WinMin/CVE-2020-8597 https://github.com/lakwsh/CVE-2020-8597 https://github.com/Dilan-Diaz/Point-to-Point-Protocol-Daemon-RCE-Vulnerability-CVE-2020-8597- http://lists.opensuse.org/opensuse-security-announce/2020-03/msg00006.html http://packetstormsecurity.com/files/156662/pppd-2.4.8-Buffer-Overflow.html http://packetstormsecurity.com/files/156802/pppd-2.4.8-Buffer-Overflow.html http://seclists.org/fulldisclosure/2020/Mar/ • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •
CVE-2019-5082
https://notcve.org/view.php?id=CVE-2019-5082
An exploitable heap buffer overflow vulnerability exists in the iocheckd service I/O-Check functionality of WAGO PFC200 Firmware version 03.01.07(13), WAGO PFC200 Firmware version 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A specially crafted set of packets can cause a heap buffer overflow, potentially resulting in code execution. An attacker can send unauthenticated packets to trigger this vulnerability. Existe una vulnerabilidad de desbordamiento del búfer de la pila explotable en la funcionalidad I-O-Check del servicio iocheckd de WAGO PFC200 Firmware versión 03.01.07(13), WAGO PFC200 Firmware versión 03.00.39(12) y WAGO PFC100 Firmware versión 03.00.39(12 ). Un conjunto de paquetes especialmente diseñado puede causar un desbordamiento del búfer de la pila, resultando potencialmente en una ejecución de código. • https://talosintelligence.com/vulnerability_reports/TALOS-2019-0874 • CWE-787: Out-of-bounds Write •
CVE-2019-18202
https://notcve.org/view.php?id=CVE-2019-18202
Information Disclosure is possible on WAGO Series PFC100 and PFC200 devices before FW12 due to improper access control. A remote attacker can check for the existence of paths and file names via crafted HTTP requests. Una divulgación de información es posible en los dispositivos WAGO Series PFC100 y PFC200 versiones anteriores a FW12, debido a un control de acceso inapropiado. Un atacante remoto puede comprobar la existencia de rutas y nombres de archivos por medio de peticiones HTTP diseñadas. • https://cert.vde.com/de-de/advisories/vde-2019-017 •
CVE-2018-5459
https://notcve.org/view.php?id=CVE-2018-5459
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. Se ha descubierto un problema de autenticación indebida en WAGO PFC200 Series 3S CoDeSys Runtime, versiones 2.3.X y 2.4.X. Un atacante puede ejecutar diferentes operaciones remotas sin autenticación gracias a la aplicación CoDeSys Runtime, que está disponible en red por defecto en el puerto 2455. • https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01 • CWE-287: Improper Authentication •
CVE-2016-9362
https://notcve.org/view.php?id=CVE-2016-9362
An issue was discovered in WAGO 750-8202/PFC200 prior to FW04 (released August 2015), WAGO 750-881 prior to FW09 (released August 2016), and WAGO 0758-0874-0000-0111. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to edit and to view settings without authenticating. Ha sido descubierto un problema en WAGO 750-8202/PFC200 anterior a FW04 (publicado en agosto de 2015), WAGO 750-881 anterior a FW09 (publicado en agosto de 2016) y WAGO 0758-0874-0000-0111. Accediendo a un localizador de recursos uniforme (URL) específico en el servidor web, un usuario malicioso puede editar y ver la configuración sin autenticarse. • http://www.securityfocus.com/bid/95074 https://ics-cert.us-cert.gov/advisories/ICSA-16-357-02 • CWE-287: Improper Authentication •