CVSS: 7.5EPSS: 0%CPEs: 24EXPL: 0

EMC Isilon OneFS is affected by a path traversal vulnerability that may potentially be exploited by attackers to compromise the affected system. Affected versions are 7.1.0 - 7.1.1.10, 7.2.0 - 7.2.1.3, and 8.0.0 - 8.0.0.1. EMC Isilon OneFS es afectada por una vulnerabilidad de recorrido transversal que potencialmente puede ser explotada por los atacantes para comprometer el sistema afectado. Las versiones afectadas son 7.1.0 - 7.1.1.10, 7.2.0 - 7.2.1.3 y 8.0.0 - 8.0.0.1. • http://www.securityfocus.com/archive/1/540338/30/0/threaded http://www.securityfocus.com/bid/97222 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 9.0EPSS: 0%CPEs: 23EXPL: 0

EMC Isilon OneFS 7.2.1.0 - 7.2.1.3, EMC Isilon OneFS 7.2.0.x, EMC Isilon OneFS 7.1.1.0 - 7.1.1.10, EMC Isilon OneFS 7.1.0.x is affected by a privilege escalation vulnerability that could potentially be exploited by attackers to compromise the affected system. EMC Isilon OneFS 7.1.0.x, EMC Isilon OneFS 7.1.0.10, EMC Isilon OneFS 7.1.0.x se ve afectada por una vulnerabilidad de escalada de privilegios que podría ser potencialmente explotada por los atacantes para comprometer el sistema afectado. • http://www.securityfocus.com/archive/1/540050/30/0/threaded http://www.securityfocus.com/bid/95800 • CWE-264: Permissions, Privileges, and Access Controls •

CVSS: 7.2EPSS: 0%CPEs: 26EXPL: 0

EMC Isilon OneFS 8.0.0.0, EMC Isilon OneFS 7.2.1.0 - 7.2.1.2, EMC Isilon OneFS 7.2.0.x, EMC Isilon OneFS 7.1.1.0 - 7.1.1.10, and EMC Isilon OneFS 7.1.0.x is affected by an LDAP injection vulnerability that could potentially be exploited by a malicious user to compromise the system. EMC Isilon OneFS 8.0.0.0, EMC Isilon OneFS 7.2.1.0 - 7.2.1.2, EMC Isilon OneFS 7.2.0.x, EMC Isilon OneFS 7.1.1.0 - 7.1.1.10 y EMC Isilon OneFS 7.1.0.x está afectado por una vulnerabilidad de inyección LDAP que podría ser potencialmente explotable por un usuario malicioso para comprometer el sistema. • http://www.securityfocus.com/archive/1/540020/30/0/threaded http://www.securityfocus.com/bid/95626 • CWE-90: Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection') •

CVSS: 6.8EPSS: 0%CPEs: 24EXPL: 0

EMC Isilon OneFS 7.1.x before 7.1.1.9 and 7.2.x before 7.2.1.2 allows local users to obtain root shell access by leveraging administrative privileges. EMC Isilon OneFS 7.1.x en versiones anteriores a 7.1.1.9 y 7.2.x en versiones anteriores a 7.2.1.2 permite a usuarios locales obtener acceso root al shell aprovechando privilegios administrativos. • http://seclists.org/bugtraq/2016/Jun/13 • CWE-264: Permissions, Privileges, and Access Controls •

CVSS: 5.9EPSS: 0%CPEs: 23EXPL: 0

EMC Isilon OneFS 7.1.x and 7.2.x before 7.2.1.3 and 8.0.x before 8.0.0.1, and IsilonSD Edge OneFS 8.0.x before 8.0.0.1, does not require SMB signing within a DCERPC session over ncacn_np, which allows man-in-the-middle attackers to spoof SMB clients by modifying the client-server data stream, a similar issue to CVE-2016-2115. EMC Isilon OneFS 7.1.x y 7.2.x en versiones anteriores a 7.2.1.3 y 8.0.x en versiones anteriores a 8.0.0.1 e IsilonSD Edge OneFS 8.0.x en versiones anteriores a 8.0.0.1, no requiere la firma SMB dentro de una sesión DCERPC sobre ncacn_np, lo que permite a atacantes man-in-the-middle suplantar clientes SMB mediante la modificación del flujo de datos cliente-servidor, un problema similar a CVE-2016-2115. • http://seclists.org/bugtraq/2016/May/117 • CWE-254: 7PK - Security Features •