Page 2 of 9 results (0.008 seconds)

CVSS: 7.1EPSS: 0%CPEs: 132EXPL: 0

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products. Se ha identificado una vulnerabilidad en la familia de switches (incluyendo las variantes SIPLUS NET) (Todas las versiones anteriores a la versión V5.2.5), familia de switches SCALANCE X-200IRT (incluyendo las variantes SIPLUS NET) (Todas las versiones anteriores a la versión V5.5.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf • CWE-306: Missing Authentication for Critical Function •

CVSS: 10.0EPSS: 0%CPEs: 132EXPL: 0

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. • https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 9.8EPSS: 0%CPEs: 132EXPL: 0

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. • https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 5.9EPSS: 0%CPEs: 132EXPL: 0

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. • https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02 • CWE-321: Use of Hard-coded Cryptographic Key CWE-798: Use of Hard-coded Credentials •