CVE-2020-14516
https://notcve.org/view.php?id=CVE-2020-14516
In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly. En Rockwell Automation FactoryTalk Services Platform versiones 6.10.00 y 6.11.00, se presenta un problema con la implementación del algoritmo de hash SHA-256 con la plataforma de servicios FactoryTalk que impide que la contraseña del usuario se procese apropiadamente • https://us-cert.cisa.gov/ics/advisories/icsa-21-054-01 • CWE-916: Use of Password Hash With Insufficient Computational Effort •
CVE-2021-22665
https://notcve.org/view.php?id=CVE-2021-22665
Rockwell Automation DriveTools SP v5.13 and below and Drives AOP v4.12 and below both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system. DriveTools SP versiones v5.13 y anteriores de Rockwell Automation y Drives AOP versiones v4.12 y anteriores, contienen una vulnerabilidad que un atacante local con privilegios limitados puede ser capaz de explotar, resultando en una escalada de privilegios y un control completo del sistema • https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1129798 https://us-cert.cisa.gov/ics/advisories/icsa-21-042-02 • CWE-427: Uncontrolled Search Path Element •
CVE-2021-22681
https://notcve.org/view.php?id=CVE-2021-22681
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores, y RSLogix 5000 versiones 16 hasta 20, usan una clave para verificar que los controladores Logix se estén comunicando con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores y RSLogix 5000: Versiones 16 hasta 20, son vulnerables porque un atacante no autenticado podría pasar por alto este mecanismo de comprobación y autenticarse con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550 , 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800 • https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03 • CWE-522: Insufficiently Protected Credentials •
CVE-2020-6088
https://notcve.org/view.php?id=CVE-2020-6088
An exploitable denial of service vulnerability exists in the ENIP Request Path Network Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability. Se presenta una vulnerabilidad de denegación de servicio explotable en la funcionalidad ENIP Request Path Network Segment de Allen-Bradley Flex IO 1794-AENT/B versión 4.003. Una petición de red especialmente diseñada puede causar una pérdida de comunicaciones con el dispositivo resultando en una denegación de servicio. • https://talosintelligence.com/vulnerability_reports/TALOS-2020-1008 • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •
CVE-2020-27265
https://notcve.org/view.php?id=CVE-2020-27265
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code. KEPServerEX: versiones v6.0 hasta v6.9, ThingWorx Kepware Server: versiones v6.8 y v6.9, ThingWorx Industrial Connectivity: Todas las versiones, OPC-Aggregator: Todas las versiones, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: versiones v7.68.804 y v7.66, Software Toolbox TOP Server: Todas las versiones 6.x, son vulnerables a un desbordamiento de búfer en la región stack de la memoria. Abrir un mensaje OPC UA específicamente diseñado podría permitir a un atacante bloquear el servidor y ejecutar código de remotamente • https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •