CVE-2024-39675
https://notcve.org/view.php?id=CVE-2024-39675
A vulnerability has been identified in RUGGEDCOM RMC30 (All versions < V4.3.10), RUGGEDCOM RMC30NC (All versions < V4.3.10), RUGGEDCOM RP110 (All versions < V4.3.10), RUGGEDCOM RP110NC (All versions < V4.3.10), RUGGEDCOM RS400 (All versions < V4.3.10), RUGGEDCOM RS400NC (All versions < V4.3.10), RUGGEDCOM RS401 (All versions < V4.3.10), RUGGEDCOM RS401NC (All versions < V4.3.10), RUGGEDCOM RS416 (All versions < V4.3.10), RUGGEDCOM RS416NC (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416P (All versions < V4.3.10), RUGGEDCOM RS416PNC (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS910 (All versions < V4.3.10), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910LNC (All versions), RUGGEDCOM RS910NC (All versions < V4.3.10), RUGGEDCOM RS910W (All versions < V4.3.10), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920LNC (All versions), RUGGEDCOM RS920W (All versions). In some configurations the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability. • https://cert-portal.siemens.com/productcert/html/ssa-170375.html • CWE-497: Exposure of Sensitive System Information to an Unauthorized Control Sphere •
CVE-2024-38867
https://notcve.org/view.php?id=CVE-2024-38867
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS). This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over to and from those ports. Se ha identificado una vulnerabilidad en SIPROTEC 5 6MD84 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 6MD85 (CP200) (Todas las versiones), SIPROTEC 5 6MD85 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 6MD86 (CP200) (Todas las versiones), SIPROTEC 5 6MD86 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 6MD89 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 6MU85 (CP300) (Todas las versiones < V9. 64), SIPROTEC 5 7KE85 (CP200) (Todas las versiones), SIPROTEC 5 7KE85 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 7SA82 (CP100) (Todas las versiones), SIPROTEC 5 7SA82 (CP150) (Todas las versiones < V9.65), SIPROTEC 5 7SA84 (CP200) (Todas las versiones), SIPROTEC 5 7SA86 (CP200) (Todas las versiones), SIPROTEC 5 7SA86 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7SA87 (CP200) (Todas versiones), SIPROTEC 5 7SA87 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7SD82 (CP100) (Todas las versiones), SIPROTEC 5 7SD82 (CP150) (Todas las versiones < V9.65), SIPROTEC 5 7SD84 (CP200) (Todas las versiones), SIPROTEC 5 7SD86 (CP200) (Todas las versiones), SIPROTEC 5 7SD86 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7SD87 (CP200) (Todas las versiones), SIPROTEC 5 7SD87 (CP300) (Todas versiones < V9.65), SIPROTEC 5 7SJ81 (CP100) (Todas las versiones < V8.89), SIPROTEC 5 7SJ81 (CP150) (Todas las versiones < V9.65), SIPROTEC 5 7SJ82 (CP100) (Todas las versiones < V8.89 ), SIPROTEC 5 7SJ82 (CP150) (Todas las versiones < V9.65), SIPROTEC 5 7SJ85 (CP200) (Todas las versiones), SIPROTEC 5 7SJ85 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7SJ86 (CP200) ( Todas las versiones), SIPROTEC 5 7SJ86 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7SK82 (CP100) (Todas las versiones < V8.89), SIPROTEC 5 7SK82 (CP150) (Todas las versiones < V9.65), SIPROTEC 5 7SK85 (CP200) (Todas las versiones), SIPROTEC 5 7SK85 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7SL82 (CP100) (Todas las versiones), SIPROTEC 5 7SL82 (CP150) (Todas las versiones < V9.65) , SIPROTEC 5 7SL86 (CP200) (Todas las versiones), SIPROTEC 5 7SL86 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7SL87 (CP200) (Todas las versiones), SIPROTEC 5 7SL87 (CP300) (Todas las versiones < V9. 65), SIPROTEC 5 7SS85 (CP200) (Todas las versiones), SIPROTEC 5 7SS85 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 7ST85 (CP200) (Todas las versiones), SIPROTEC 5 7ST85 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 7ST86 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 7SX82 (CP150) (Todas las versiones < V9.65), SIPROTEC 5 7SX85 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7UM85 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 7UT82 (CP100) (Todas las versiones), SIPROTEC 5 7UT82 (CP150) (Todas las versiones < V9.65), SIPROTEC 5 7UT85 (CP200) (Todas las versiones ), SIPROTEC 5 7UT85 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7UT86 (CP200) (Todas las versiones), SIPROTEC 5 7UT86 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7UT87 (CP200) ( Todas las versiones), SIPROTEC 5 7UT87 (CP300) (Todas las versiones < V9.65), SIPROTEC 5 7VE85 (CP300) (Todas las versiones < V9.64), SIPROTEC 5 7VK87 (CP200) (Todas las versiones), SIPROTEC 5 7VK87 (CP300 ) (Todas las versiones < V9.65), SIPROTEC 5 7VU85 (CP300) (Todas las versiones < V9.64), Módulo de comunicación SIPROTEC 5 ETH-BA-2EL (Rev.1) (Todas las versiones < V9.62 instaladas en CP150 y dispositivos CP300), módulo de comunicación SIPROTEC 5 ETH-BA-2EL (Rev.1) (todas las versiones instaladas en dispositivos CP200), módulo de comunicación SIPROTEC 5 ETH-BA-2EL (Rev.1) (todas las versiones < V8.89 instaladas en dispositivos CP100), Módulo de comunicación SIPROTEC 5 ETH-BB-2FO (Rev. 1) (Todas las versiones instaladas en dispositivos CP200), Módulo de comunicación SIPROTEC 5 ETH-BB-2FO (Rev. 1) (Todas las versiones < V9.62 instaladas en dispositivos CP150 y CP300), Módulo de comunicación SIPROTEC 5 ETH-BB-2FO ( Rev. 1) (Todas las versiones < V8.89 instaladas en dispositivos CP100), Mó A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All v • https://cert-portal.siemens.com/productcert/html/ssa-750499.html • CWE-326: Inadequate Encryption Strength •
CVE-2023-52891
https://notcve.org/view.php?id=CVE-2023-52891
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. Se ha identificado una vulnerabilidad en SIMATIC Energy Manager Basic (todas las versiones < V7.5), SIMATIC Energy Manager PRO (todas las versiones < V7.5), SIMATIC IPC DiagBase (todas las versiones), SIMATIC IPC DiagMonitor (todas las versiones), SIMIT V10 (Todas las versiones), SIMIT V11 (Todas las versiones < V11.1). El SDK del servidor OPC UA basado en Unified Automation .NET anterior a 3.2.2 utilizado en productos Siemens se ve afectado por una vulnerabilidad similar a la documentada en CVE-2023-27321 para la implementación del estándar OPC Foundation UA .NET. • https://cert-portal.siemens.com/productcert/html/ssa-088132.html • CWE-1325: Improperly Controlled Sequential Memory Allocation •
CVE-2023-52237
https://notcve.org/view.php?id=CVE-2023-52237
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. The web server of the affected devices allow a low privileged user to access hashes and password salts of all system's users, including admin users. An attacker could use the obtained information to brute force the passwords offline. Se ha identificado una vulnerabilidad en RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100NC, RUGGEDCOM M2200 , RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969NC, RUGGEDCOM RMC30 , RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600 F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS4 16PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS800 0HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900 , RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4. X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, GGEDCOM RS900M-STND-XX , RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) 5. • https://cert-portal.siemens.com/productcert/html/ssa-170375.html • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •
CVE-2023-32735
https://notcve.org/view.php?id=CVE-2023-32735
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 Safety V16 (todas las versiones < V16 Update 7), SIMATIC STEP 7 Safety V17 (todas las versiones < V17 Update 7), SIMATIC STEP 7 Safety V18 (todas las versiones < V18 Update 2), SIMATIC STEP 7 V16 (todas las versiones < V16 Update 7), SIMATIC STEP 7 V17 (todas las versiones < V17 Update 7), SIMATIC STEP 7 V18 (todas las versiones < V18 Update 2), SIMATIC WinCC Unified V16 (todas las versiones < V16 Update 7), SIMATIC WinCC Unified V17 (todas las versiones < V17 Update 7), SIMATIC WinCC Unified V18 (todas las versiones < V18 Update 2), SIMATIC WinCC V16 (todas las versiones < V16.7), SIMATIC WinCC V17 (todas las versiones < V17.7), SIMATIC WinCC V18 (todas las versiones < V18 Update 2), SIMOCODE ES V16 (todas las versiones < V16 Update 7), SIMOCODE ES V17 (todas las versiones < V17 Update 7), SIMOCODE ES V18 (todas las versiones < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (Todas las versiones), SIMOTION SCOUT TIA V5.4 SP3 (Todas las versiones), SIMOTION SCOUT TIA V5.5 SP1 (Todas las versiones), SINAMICS Startdrive V16 (Todas las versiones), SINAMICS Startdrive V17 (Todas las versiones), SINAMICS Startdrive V18 (todas las versiones), SIRIUS Safety ES V17 (todas las versiones < V17 Update 7), SIRIUS Safety ES V18 (todas las versiones < V18 Update 2), SIRIUS Soft Starter ES V17 (todas las versiones < V17 Update 7), SIRIUS Soft Starter ES V18 (Todas las versiones < V18 Actualización 2), Soft Starter ES V16 (Todas las versiones < V16 Actualización 7), TIA Portal Cloud V3.0 (Todas las versiones < V18 Actualización 2). Las aplicaciones afectadas no restringen adecuadamente .NET BinaryFormatter al deserializar perfiles de configuración de hardware. • https://cert-portal.siemens.com/productcert/html/ssa-779936.html • CWE-502: Deserialization of Untrusted Data •