5 results (0.012 seconds)

CVSS: 10.0EPSS: 0%CPEs: 1EXPL: 0

For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer. Para los productos ABB Ability™ System 800xA de ABB y extensiones de sistema relacionadas versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe versiones 1.0, 1.1 y 2.0, Symphony Plus -S+ Engineering versiones 1.1 hasta 2.2, Composer Harmony versiones 5.1, 6.0 y 6.1, Melody Composer versiones 5.3, 6.1/6.2 y SPE for Melody versión 1.0SPx (Composer versión 6.3), Harmony OPC Server (HAOPC) Standalone versiones 6.0, 6.1 y 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A versiones 1.3 y 1.4, Advant® OCS AC100 OPC Server versiones 5.1, 6.0 y 6.1, Composer CTK versiones 6.1 y 6.2, AdvaBuild versiones 3.7 SP1 y SP2, OPCServer para MOD 300 (non-800xA) versión 1.4, OPC Data Link versiones 2.1 y 2.2, Knowledge Manager versiones 8.0, 9.0 y 9.1, Manufacturing Operations Management versiones 1812 y 1909, los datos confidenciales se escriben en un archivo no protegido. Un atacante que explote con éxito esta vulnerabilidad podría tomar el control total de la computadora. • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-922: Insecure Storage of Sensitive Information •

CVSS: 7.8EPSS: 0%CPEs: 13EXPL: 0

For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code. Para el componente Central Licensing Server usado en los productos de ABB Ability™ System 800xA de ABB y extensiones de sistema relacionadas versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe versiones 1.0, 1.1 y 2.0, Symphony Plus -S+ Operations versiones 3.0 hasta 3.2 Symphony Plus -S+ Engineering versiones 1.1 hasta 2.2, Composer Harmony versiones 5.1, 6.0 y 6.1, Melody Composer versiones 5.3, 6.1/6.2 y SPE para Melody versión 1.0SPx (Composer versión 6.3), Harmony OPC Server (HAOPC) Standalone versiones 6.0, 6.1 y 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A versiones 1.3 y 1.4, Advant® OCS AC100 OPC Server versiones 5.1, 6.0 y 6.1, Composer CTK versiones 6.1 y 6.2, AdvaBuild versión 3.7 SP1 y SP2, OPCServer para MOD 300 (non-800xA) versión 1.4, OPC Data Link versiones 2.1 y 2.2, Knowledge Manager versiones 8.0, 9.0 y 9.1, Manufacturing Operations Management versiones 1812 y 1909, unos permisos de archivo débiles permiten a un atacante autenticado bloquear el manejo de la licencia, escalar sus privilegios y ejecutar código arbitrario. • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch https://www.us-cert.gov/ics/advisories/icsa-20-154-04 • CWE-275: Permission Issues CWE-276: Incorrect Default Permissions •

CVSS: 7.5EPSS: 0%CPEs: 23EXPL: 0

For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service. Para el componente Central Licensing Server utilizado en los productos ABB Ability™ System 800xA y las extensiones del sistema relacionadas, versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe 1.0, 1.1 y 2.0, Symphony Plus -S+ Operations 3.0 a 3. 2 Symphony Plus -S+ Engineering 1.1 a 2.2, Composer Harmony 5.1, 6.0 y 6.1, Melody Composer 5.3, 6.1/6.2 y SPE para Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 y 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1. 3 y 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 y 6.1, Composer CTK 6.1 y 6.2, AdvaBuild 3.7 SP1 y SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 y 2.2, Knowledge Manager 8.0, 9.0 y 9. 1, Manufacturing Operations Management 1812 y 1909, ABB AbilityTM SCADAvantage versiones 5.1 a 5.6.5, existe una debilidad en la validación de la entrada que permite a un atacante alterar las licencias asignadas a los nodos del sistema enviando mensajes especialmente diseñados al servicio web CLS • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 23EXPL: 0

For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service. Para el componente Central Licensing Server utilizado en los productos ABB Ability™ System 800xA y las extensiones del sistema relacionadas, versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe 1.0, 1.1 y 2.0, Symphony Plus -S+ Operations 3.0 a 3. 2 Symphony Plus -S+ Engineering 1.1 a 2.2, Composer Harmony 5.1, 6.0 y 6.1, Melody Composer 5.3, 6.1/6.2 y SPE para Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 y 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1. 3 y 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 y 6.1, Composer CTK 6.1 y 6.2, AdvaBuild 3.7 SP1 y SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 y 2.2, Knowledge Manager 8.0, 9.0 y 9. 1, Manufacturing Operations Management 1812 y 1909, ABB AbilityTM SCADAvantage versiones 5.1 a 5.6.5, existe una debilidad en la validación de la entrada que permite a un atacante bloquear la gestión de licencias enviando mensajes especialmente diseñados al servicio web CLS • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-20: Improper Input Validation •

CVSS: 9.8EPSS: 1%CPEs: 22EXPL: 0

For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling. Para el componente Central Licensing Server utilizado en los productos ABB Ability™ System 800xA y las extensiones del sistema relacionadas, versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe 1.0, 1.1 y 2.0, Symphony Plus -S+ Operations 3.0 a 3. 2 Symphony Plus -S+ Engineering 1.1 a 2.2, Composer Harmony 5.1, 6.0 y 6.1, Melody Composer 5.3, 6.1/6.2 y SPE para Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 y 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1. 3 y 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 y 6.1, Composer CTK 6.1 y 6.2, AdvaBuild 3.7 SP1 y SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 y 2.2, Knowledge Manager 8.0, 9.0 y 9. 1, Manufacturing Operations Management 1812 y 1909, ABB AbilityTM SCADAvantage versiones 5.1 a 5.6.5. existe una vulnerabilidad de Inyección de Entidades Externas XML que permite a un atacante leer o llamar archivos arbitrarios desde el servidor de licencias y/o desde la red y también bloquear el manejo de licencias • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-91: XML Injection (aka Blind XPath Injection) •