CVE-2024-50377
https://notcve.org/view.php?id=CVE-2024-50377
26 Nov 2024 — A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password. • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50377 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2024-50376
https://notcve.org/view.php?id=CVE-2024-50376
26 Nov 2024 — A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID. • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50376 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2024-50375
https://notcve.org/view.php?id=CVE-2024-50375
26 Nov 2024 — A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point. • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50375 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2024-50374
https://notcve.org/view.php?id=CVE-2024-50374
26 Nov 2024 — A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the s... • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50374 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2024-50373
https://notcve.org/view.php?id=CVE-2024-50373
26 Nov 2024 — A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the s... • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50373 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2024-50372
https://notcve.org/view.php?id=CVE-2024-50372
26 Nov 2024 — A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the s... • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50372 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2024-50371
https://notcve.org/view.php?id=CVE-2024-50371
26 Nov 2024 — A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the s... • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50371 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2024-50370
https://notcve.org/view.php?id=CVE-2024-50370
26 Nov 2024 — A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the s... • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50370 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2024-50369
https://notcve.org/view.php?id=CVE-2024-50369
26 Nov 2024 — A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands. • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50369 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2024-50368
https://notcve.org/view.php?id=CVE-2024-50368
26 Nov 2024 — A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands. • https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50368 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •