12 results (0.014 seconds)

CVSS: 4.3EPSS: 0%CPEs: 1EXPL: 0

An authenticated user using Advantech WebAccess SCADA in versions 9.0.3 and prior can use API functions to disclose project names and paths from other users. Un usuario autenticado usando Advantech WebAccess SCADA en versiones 9.0.3 y anteriores, puede usar funciones de la API para revelar nombres de proyectos y rutas de otros usuarios • https://us-cert.cisa.gov/ics/advisories/icsa-21-285-01 • CWE-862: Missing Authorization •

CVSS: 6.1EPSS: 0%CPEs: 5EXPL: 0

In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an origin validation error vulnerability has been identified, which may allow an attacker can create a malicious web site, steal session cookies, and access data of authenticated users. En Advantech WebAccess en versiones V8.2_20170817 y anteriores, WebAccess en versiones V8.3.0 y anteriores, WebAccess Dashboard en versiones V.2.0.15 y anteriores, WebAccess Scada Node en versiones anteriores a la 8.3.1 y WebAccess/NMS 2.0.3 y anteriores, se ha identificado una vulnerabilidad de error de validación de origen que podría permitir que un atacante cree un sitio web malicioso, robe cookies de sesión o acceda a los datos de los usuarios autenticados. • http://www.securityfocus.com/bid/104190 https://ics-cert.us-cert.gov/advisories/ICSA-18-135-01 • CWE-346: Origin Validation Error CWE-384: Session Fixation •

CVSS: 10.0EPSS: 0%CPEs: 5EXPL: 0

In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a TFTP application has unrestricted file uploads to the web application without authorization, which may allow an attacker to execute arbitrary code. En Advantech WebAccess en versiones V8.2_20170817 y anteriores, WebAccess en versiones V8.3.0 y anteriores, WebAccess Dashboard en versiones V.2.0.15 y anteriores, WebAccess Scada Node en versiones anteriores a la 8.3.1 y WebAccess/NMS 2.0.3 y anteriores, una aplicación TFTP tiene subidas de archivo sin restricciones, lo que podría permitir que un atacante ejecute código arbitrario. This vulnerability allows remote attackers to execute code on vulnerable installations of Advantech WebAccess NMS. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the TFTP service. The issue results from the lack of proper validation of user-supplied data, which can allow for the upload of arbitrary files. • http://www.securityfocus.com/bid/104190 https://ics-cert.us-cert.gov/advisories/ICSA-18-135-01 • CWE-264: Permissions, Privileges, and Access Controls CWE-434: Unrestricted Upload of File with Dangerous Type •

CVSS: 9.8EPSS: 7%CPEs: 5EXPL: 0

In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a heap-based buffer overflow vulnerability has been identified, which may allow an attacker to execute arbitrary code. En Advantech WebAccess en versiones V8.2_20170817 y anteriores, WebAccess en versiones V8.3.0 y anteriores, WebAccess Dashboard en versiones V.2.0.15 y anteriores, WebAccess Scada Node en versiones anteriores a la 8.3.1 y WebAccess/NMS 2.0.3 y anteriores, se ha identificado una vulnerabilidad de desbordamiento de búfer basado en memoria dinámica (heap) que podría permitir que un atacante ejecute código arbitrario. This vulnerability allows remote attackers to execute arbitrary code on vulnerable instances of Advantech WebAccess. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of the 0x13C80 IOCTL in the BwOpcTool subsystem. When parsing the NamedObject structure, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. • http://www.securityfocus.com/bid/104190 https://ics-cert.us-cert.gov/advisories/ICSA-18-135-01 • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 5EXPL: 0

In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an improper privilege management vulnerability may allow an authenticated user to modify files when read access should only be given to the user. En Advantech WebAccess en versiones V8.2_20170817 y anteriores, WebAccess en versiones V8.3.0 y anteriores, WebAccess Dashboard en versiones V.2.0.15 y anteriores, WebAccess Scada Node en versiones anteriores a la 8.3.1 y WebAccess/NMS 2.0.3 y anteriores, una vulnerabilidad de gestión de privilegios incorrecta podría permitir que un usuario autenticado modifique archivos cuando el acceso de lectura solo se debería otorgar al usuario. This vulnerability allows local attackers to escalate privilege on vulnerable installations of Advantech WebAccess Node. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the access control that is set and modified during the installation of the product. The product installation weakens access control restrictions of pre-existing system files and sets weak access control restrictions on new files. • http://www.securityfocus.com/bid/104190 https://ics-cert.us-cert.gov/advisories/ICSA-18-135-01 • CWE-269: Improper Privilege Management •