7 results (0.002 seconds)

CVSS: 7.8EPSS: 0%CPEs: 24EXPL: 0

31 Aug 2022 — AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-... • https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-01 • CWE-427: Uncontrolled Search Path Element •

CVSS: 7.8EPSS: 0%CPEs: 24EXPL: 0

31 Aug 2022 — AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL version... • https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-01 • CWE-319: Cleartext Transmission of Sensitive Information •

CVSS: 9.8EPSS: 1%CPEs: 13EXPL: 0

07 Jul 2020 — This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. • https://www.zerodayinitiative.com/advisories/ZDI-20-807 • CWE-306: Missing Authentication for Critical Function •

CVSS: 7.5EPSS: 0%CPEs: 13EXPL: 0

07 Jul 2020 — This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authentication mechanism. The issue is due to insufficient authentication on post-authentication requests. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from unauthenticated users. • https://www.zerodayinitiative.com/advisories/ZDI-20-805 • CWE-287: Improper Authentication •

CVSS: 5.9EPSS: 0%CPEs: 13EXPL: 0

07 Jul 2020 — This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. When transmitting passwords, the process encrypts them in a recoverable format. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. • https://www.zerodayinitiative.com/advisories/ZDI-20-806 • CWE-261: Weak Encoding for Password CWE-326: Inadequate Encryption Strength •

CVSS: 7.5EPSS: 1%CPEs: 13EXPL: 0

07 Jul 2020 — This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of proper input validation prior to further processing user requests. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. • https://www.zerodayinitiative.com/advisories/ZDI-20-809 • CWE-20: Improper Input Validation •

CVSS: 9.8EPSS: 1%CPEs: 13EXPL: 0

07 Jul 2020 — This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device.... • https://www.zerodayinitiative.com/advisories/ZDI-20-808 • CWE-306: Missing Authentication for Critical Function •