6 results (0.028 seconds)

CVSS: 6.1EPSS: 0%CPEs: 10EXPL: 0

Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with physical access to gain unauthorized access to view/update system configuration or data. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI. Baxter ExactaMix EM 2400 y EM 1200, Versiones ExactaMix EM2400 Versiones 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versiones 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versiones 1.10, 1.11 y 1.13, y ExactaMix EM1200 Versiones 1.1, 1.2 y 1.4, poseen credenciales embebidas de cuenta administrativa para la aplicación ExactaMix. Una explotación con éxito de esta vulnerabilidad puede permitir que un atacante con acceso físico consiga acceso no autorizado para visualizar y actualizar la configuración o los datos del sistema. • https://www.us-cert.gov/ics/advisories/icsma-20-170-01 • CWE-259: Use of Hard-coded Password CWE-798: Use of Hard-coded Credentials •

CVSS: 10.0EPSS: 0%CPEs: 10EXPL: 0

Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI. Baxter ExactaMix EM 2400 y EM 1200, Versiones ExactaMix EM2400 Versiones 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versiones 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versiones 1.10, 1.11, 1.13, 1.14 y ExactaMix EM1200 Versiones 1.1, 1.2 , 1.4 y 1.5, poseen credenciales embebidas de cuenta administrativa para el sistema operativo de ExactaMix. Una explotación con éxito de esta vulnerabilidad puede permitir a un atacante que haya obtenido acceso no autorizado a los recursos del sistema, incluido el acceso para ejecutar software o para visualizar y actualizar archivos, directorios o la configuración del sistema. • https://www.us-cert.gov/ics/advisories/icsma-20-170-01 • CWE-259: Use of Hard-coded Password CWE-798: Use of Hard-coded Credentials •

CVSS: 7.5EPSS: 0%CPEs: 6EXPL: 0

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI. Los sistemas Baxter ExactaMix EM 2400 Versiones 1.10, 1.11 y ExactaMix EM1200 Versiones 1.1, 1.2, usan mensajes de texto sin cifrar para comunicar información de pedidos con un sistema de ingreso de pedidos. Esto podría permitir a un atacante con acceso a la red visualizar datos confidenciales, incluyendo la PHI • https://www.us-cert.gov/ics/advisories/icsma-20-170-01 • CWE-319: Cleartext Transmission of Sensitive Information •

CVSS: 9.1EPSS: 0%CPEs: 6EXPL: 0

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI. Los sistemas Baxter ExactaMix EM 2400 Versiones 1.10, 1.11 y ExactaMix EM1200 Versiones 1.1, 1.2, almacenan datos del dispositivo con información confidencial en una base de datos sin cifrar. Esto podría permitir a un atacante con acceso a la red visualizar o modificar datos confidenciales, incluyendo la PHI • https://www.us-cert.gov/ics/advisories/icsma-20-170-01 • CWE-311: Missing Encryption of Sensitive Data CWE-312: Cleartext Storage of Sensitive Information •

CVSS: 6.1EPSS: 0%CPEs: 8EXPL: 0

Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users from gaining access to the operating system and editing the application startup script. Successful exploitation of this vulnerability may allow an attacker to alter the startup script as the limited-access user. Baxter ExactaMix EM 2400 Versiones 1.10, 1.11 y 1.13 y ExactaMix EM1200 Versiones 1.1, 1.2 y 1.4, no restringe que los usuarios no administrativos consigan acceso al sistema operativo y editen el script de inicio de la aplicación. Una explotación con éxito de esta vulnerabilidad puede permitir a un atacante alterar el script de inicio como el usuario de acceso limitado • https://www.us-cert.gov/ics/advisories/icsma-20-170-01 • CWE-668: Exposure of Resource to Wrong Sphere •