CVE-2023-28175
https://notcve.org/view.php?id=CVE-2023-28175
Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request. • https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-863: Incorrect Authorization •
CVE-2020-6785 – Uncontrolled Search Path Element in Bosch BVMS and BVMS Viewer
https://notcve.org/view.php?id=CVE-2020-6785
Loading a DLL through an Uncontrolled Search Path Element in Bosch BVMS and BVMS Viewer in versions 10.1.0, 10.0.1, 10.0.0 and 9.0.0 and older potentially allows an attacker to execute arbitrary code on a victim's system. This affects both the installer as well as the installed application. This also affects Bosch DIVAR IP 7000 R2, Bosch DIVAR IP all-in-one 5000 and Bosch DIVAR IP all-in-one 7000 with installers and installed BVMS versions prior to BVMS 10.1.1. Cargar una DLL mediante un Elemento de Ruta de Búsqueda no Controlada en Bosch BVMS y BVMS Viewer en las versiones 10.1.0, 10.0.1, 10.0.0 y 9.0.0 y anteriores, permite a un atacante ejecutar código arbitrario en el sistema de una víctima. Esto afecta tanto al instalador como a la aplicación instalada. • https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html • CWE-427: Uncontrolled Search Path Element •