4 results (0.008 seconds)

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 0

An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. Un manejo inadecuado de una solicitud API con formato incorrecto a un servidor API en los productos de software Bosch BT puede permitir que un atacante no autenticado provoque una situación de denegación de servicio (DoS). • https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html • CWE-703: Improper Check or Handling of Exceptional Conditions •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from. Llamar un ejecutable mediante un Elemento de Ruta de Búsqueda no Controlada en el instalador de Bosch Video Streaming Gateway versiones hasta 6.45.10 incluyéndola, permite a un atacante ejecutar código arbitrario en el sistema de la víctima. Un requisito previo es que la víctima sea engañada para colocar un exe malicioso en el mismo directorio desde el que se inicia el instalador • https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html • CWE-427: Uncontrolled Search Path Element •

CVSS: 10.0EPSS: 0%CPEs: 23EXPL: 0

Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 <= 6.45.08, 6.44 <= 6.44.022, 6.43 <= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 <= 3.62.0019 and DIVAR IP 5000 <= 3.80.0039 if the corresponding port 8023 has been opened in the device's firewall. • https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html • CWE-306: Missing Authentication for Critical Function •

CVSS: 9.8EPSS: 0%CPEs: 27EXPL: 0

A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface. Una vulnerabilidad de seguridad encontrada recientemente impacta a todas las versiones 9.0 y anteriores de Bosch Video Management System (BVMS), DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). La vulnerabilidad potencialmente permite la ejecución no autorizada de código en el sistema por medio de la interfaz de red. • https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf • CWE-787: Out-of-bounds Write •