CVSS: 8.6EPSS: 0%CPEs: 6EXPL: 0

18 Aug 2021 — A vulnerability in Server Name Identification (SNI) request filtering of Cisco Web Security Appliance (WSA), Cisco Firepower Threat Defense (FTD), and the Snort detection engine could allow an unauthenticated, remote attacker to bypass filtering technology on an affected device and exfiltrate data from a compromised host. This vulnerability is due to inadequate filtering of the SSL handshake. An attacker could exploit this vulnerability by using data from the SSL client hello packet to communicate with an e... • https://lists.debian.org/debian-lts-announce/2023/02/msg00011.html • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 6.5EPSS: 0%CPEs: 9EXPL: 0

06 May 2021 — A vulnerability in the web-based management interface of Cisco AsyncOS Software for Cisco Content Security Management Appliance (SMA), Cisco Email Security Appliance (ESA), and Cisco Web Security Appliance (WSA) could allow an authenticated, remote attacker to access sensitive information on an affected device. The vulnerability exists because confidential information is included in HTTP requests that are exchanged between the user and the device. An attacker could exploit this vulnerability by looking at t... • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-esa-wsa-sma-info-gY2AEz2H • CWE-540: Inclusion of Sensitive Information in Source Code •

CVSS: 7.4EPSS: 0%CPEs: 1EXPL: 0

15 Jan 2020 — Cisco IronPort Web Security Appliance up to and including 7.5 does not validate the basic constraints of the certificate authority which could lead to MITM attacks Cisco IronPort Web Security Appliance versiones hasta 7.5 incluyéndola, no comprueba las restricciones básicas del certificado de autoridad que podría conllevar a ataques de tipo MITM. • http://www.securityfocus.com/bid/52981 • CWE-20: Improper Input Validation •

CVSS: 5.9EPSS: 0%CPEs: 1EXPL: 0

15 Jan 2020 — Cisco IronPort Web Security Appliance does not check for certificate revocation which could lead to MITM attacks Cisco IronPort Web Security Appliance no comprueba la revocación del certificado, lo que podría conllevar a ataques de tipo MITM. • http://www.securityfocus.com/bid/52981 • CWE-295: Improper Certificate Validation •

CVSS: 6.4EPSS: 0%CPEs: 1EXPL: 0

15 Jan 2020 — Cisco IronPort Web Security Appliance AsyncOS software prior to 7.5 has a SSL Certificate Caching vulnerability which could allow man-in-the-middle attacks El software Cisco IronPort Web Security Appliance AsyncOS versiones anteriores a 7.5, presenta una vulnerabilidad de Almacenamiento en Caché de Certificado SSL lo que podría permitir ataques de tipo man-in-the-middle. • http://www.securityfocus.com/bid/52981 • CWE-20: Improper Input Validation •

CVSS: 6.1EPSS: 0%CPEs: 6EXPL: 1

10 Jun 2014 — Cross-site scripting (XSS) vulnerability in the web management interface in Cisco AsyncOS on the Email Security Appliance (ESA) 8.0, Web Security Appliance (WSA) 8.0 (.5 Hot Patch 1) and earlier, and Content Security Management Appliance (SMA) 8.3 and earlier allows remote attackers to inject arbitrary web script or HTML via a crafted parameter, as demonstrated by the date_range parameter to monitor/reports/overview on the IronPort ESA, aka Bug IDs CSCun07998, CSCun07844, and CSCun07888. Vulnerabilidad de X... • http://packetstormsecurity.com/files/127004/Cisco-Ironport-Email-Security-Virtual-Appliance-8.0.0-671-XSS.html • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 9.0EPSS: 0%CPEs: 4EXPL: 0

27 Jun 2013 — The web framework in IronPort AsyncOS on Cisco Web Security Appliance devices before 7.1.3-013, 7.5 before 7.5.0-838, and 7.7 before 7.7.0-550 allows remote authenticated users to execute arbitrary commands via crafted command-line input in a URL sent over IPv4, aka Bug ID CSCzv69294. El framework web de IronPort AsyncOS en dispositivos Cisco Web Security Appliance antes v7.1.3-013, v7.5 antes de v7.5.0-838, y v7.7 antes de v7.7.0-550 permite a los usuarios autenticados remotamente ejecutar código arbitrari... • http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20130626-wsa • CWE-94: Improper Control of Generation of Code ('Code Injection') •

CVSS: 9.0EPSS: 0%CPEs: 11EXPL: 0

27 Jun 2013 — The web framework in IronPort AsyncOS on Cisco Web Security Appliance devices before 7.1.3-013, 7.5 before 7.5.0-838, and 7.7 before 7.7.0-550; Email Security Appliance devices before 7.1.5-104, 7.3 before 7.3.2-026, 7.5 before 7.5.2-203, and 7.6 before 7.6.3-019; and Content Security Management Appliance devices before 7.2.2-110, 7.7 before 7.7.0-213, and 7.8 and 7.9 before 7.9.1-102 allows remote authenticated users to execute arbitrary commands via crafted command-line input in a URL, aka Bug IDs CSCzv85... • http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20130626-esa • CWE-94: Improper Control of Generation of Code ('Code Injection') •

CVSS: 7.8EPSS: 0%CPEs: 11EXPL: 0

27 Jun 2013 — The management GUI in the web framework in IronPort AsyncOS on Cisco Web Security Appliance devices before 7.1.3-013, 7.5 before 7.5.0-838, and 7.7 before 7.7.0-602; Email Security Appliance devices before 7.1.5-106 and 7.3, 7.5, and 7.6 before 7.6.3-019; and Content Security Management Appliance devices before 7.9.1-102 and 8.0 before 8.0.0-404 allows remote attackers to cause a denial of service (system hang) via a series of (1) HTTP or (2) HTTPS requests to a management interface, aka Bug IDs CSCzv58669,... • http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20130626-esa • CWE-399: Resource Management Errors •