14 results (0.007 seconds)

CVSS: 9.0EPSS: 0%CPEs: 16EXPL: 0

23 Mar 2023 — The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device. • https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 7.5EPSS: 0%CPEs: 16EXPL: 0

03 Aug 2021 — In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. En CODESYS V3 web server versiones anteriores a 3.5.17.10, los archivos o directorios son accesibles para las partes externas • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=16803&token=0b8edf9276dc39ee52f43026c415c5b38085d90a&download= • CWE-552: Files or Directories Accessible to External Parties •

CVSS: 9.8EPSS: 0%CPEs: 16EXPL: 0

03 Aug 2021 — CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. CODESYS Control Runtime system versiones anteriores a 3.5.17.10, presenta un Desbordamiento de Buffer en la región Heap de la memoria • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=14805&token=f0b86f99bb302ddd4aadec483aed5f5d3fddbf1a&download= • CWE-787: Out-of-bounds Write •

CVSS: 7.5EPSS: 0%CPEs: 24EXPL: 0

03 May 2021 — CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages. El sistema CODESYS Control Runtime versiones anteriores a 3.5.17.0, presenta una comprobación inapropiada de entrada. Los atacantes pueden enviar paquetes de comunicación diseñados para cambiar el esquema de direccionamiento del enrutador y pueden redireccionar, ag... • https://customers.codesys.com/index.php • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 17EXPL: 1

22 Jul 2020 — CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation. El sistema del tiempo de ejecución de Control CODESYS, versiones anteriores a 3.5.16.10, permite una Asignación de Memoria No Controlada • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=13199&token=3e283c3e73fed61f7c181a7fa1169477efaf0c58&download= • CWE-401: Missing Release of Memory after Effective Lifetime •

CVSS: 6.5EPSS: 0%CPEs: 12EXPL: 0

14 May 2020 — An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation. Se detectó un problema en CODESYS Development System versiones anteriores a 3.5.16.0. CODESYS WebVisu y CODESYS Remote TargetVisu son susceptibles a una escalada de privilegios. • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=13136&token=c267875c01ea70bc9613bc39c684eedc17f55420&download= •

CVSS: 10.0EPSS: 0%CPEs: 15EXPL: 1

26 Mar 2020 — CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. El servidor web CODESYS versiones V3 anteriores a 3.5.15.40, como es usado en los sistemas de tiempo de ejecución CODESYS Control, presenta un desbordamiento del búfer. • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=13078&token=de344ca65252463cc581ef144e0c53bd97b8f211&download= • CWE-787: Out-of-bounds Write •

CVSS: 6.5EPSS: 1%CPEs: 16EXPL: 1

24 Jan 2020 — CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition. CODESYS Control versión V3, Gateway versión V3 y HMI versiones V3 anteriores a 3.5.15.30, permiten una asignación de memoria no controlada que puede resultar en una condición de denegación de servicio remota. • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12977&token=33f948eed0c2fd69d238d9515779be337ef7592d&download= • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 9.8EPSS: 0%CPEs: 14EXPL: 1

20 Nov 2019 — CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. El servidor web CODESYS 3 versiones anteriores a la versión 3.5.15.20, distribuido con los sistemas de tiempo de ejecución CODESYS Control, tiene un desbordamiento de búfer. • https://customers.codesys.com/fileadmin/data/customers/security/2019/Advisory2019-10_CDS-68341.pdf • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •

CVSS: 6.5EPSS: 0%CPEs: 10EXPL: 0

17 Sep 2019 — 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, todas las versiones desde 3.5.11.0 hasta 3.5.15.0, permite a un atacante enviar peticiones diseñadas desde un cliente OPC UA confiable que causa una desreferencia del puntero NULL, lo que puede dese... • https://www.us-cert.gov/ics/advisories/icsa-19-255-04 • CWE-476: NULL Pointer Dereference •