
CVE-2025-4445 – D-Link DIR-605L wake_on_lan command injection
https://notcve.org/view.php?id=CVE-2025-4445
09 May 2025 — A vulnerability classified as critical has been found in D-Link DIR-605L 2.13B01. Affected is the function wake_on_lan. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure. • https://github.com/jylsec/vuldb/blob/main/D-Link/dlink_dir605l/Command_injection-wake_on_lan-mac/README.md • CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') •

CVE-2025-4443 – D-Link DIR-605L sub_454F2C command injection
https://notcve.org/view.php?id=CVE-2025-4443
08 May 2025 — A vulnerability was found in D-Link DIR-605L 2.13B01. It has been rated as critical. This issue affects the function sub_454F2C. The manipulation of the argument sysCmd leads to command injection. The attack may be initiated remotely. • https://github.com/jylsec/vuldb/blob/main/D-Link/dlink_dir605l/Command_injection-sub_454F2C-sysCmd/README.md • CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') •

CVE-2025-4442 – D-Link DIR-605L formSetWAN_Wizard55 buffer overflow
https://notcve.org/view.php?id=CVE-2025-4442
08 May 2025 — A vulnerability was found in D-Link DIR-605L 2.13B01. It has been declared as critical. This vulnerability affects the function formSetWAN_Wizard55. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. • https://github.com/jylsec/vuldb/blob/main/D-Link/dlink_dir605l/Buffer_overflow-formSetWAN_Wizard55-curTime/README.md • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •

CVE-2025-4441 – D-Link DIR-605L formSetWAN_Wizard534 buffer overflow
https://notcve.org/view.php?id=CVE-2025-4441
08 May 2025 — A vulnerability was found in D-Link DIR-605L 2.13B01. It has been classified as critical. This affects the function formSetWAN_Wizard534. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. • https://github.com/jylsec/vuldb/blob/main/D-Link/dlink_dir605l/Buffer_overflow-formSetWAN_Wizard534-curTime/README.md • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •

CVE-2025-2553 – D-Link DIR-618/DIR-605L formVirtualServ access control
https://notcve.org/view.php?id=CVE-2025-2553
20 Mar 2025 — A vulnerability was found in D-Link DIR-618 and DIR-605L 2.02/3.02. It has been rated as problematic. This issue affects some unknown processing of the file /goform/formVirtualServ. The manipulation leads to improper access controls. The attack needs to be approached within the local network. • https://lavender-bicycle-a5a.notion.site/D-Link-DIR-605L-formVirtualServ-1b153a41781f80b98645c3f7f4c5f4ae?pvs=4 • CWE-266: Incorrect Privilege Assignment CWE-284: Improper Access Control •

CVE-2025-2552 – D-Link DIR-618/DIR-605L formTcpipSetup access control
https://notcve.org/view.php?id=CVE-2025-2552
20 Mar 2025 — A vulnerability was found in D-Link DIR-618 and DIR-605L 2.02/3.02. It has been declared as problematic. This vulnerability affects unknown code of the file /goform/formTcpipSetup. The manipulation leads to improper access controls. Access to the local network is required for this attack to succeed. • https://lavender-bicycle-a5a.notion.site/D-Link-DIR-605L-formTcpipSetup-1b153a41781f80a7967ae08c81147a39?pvs=4 • CWE-266: Incorrect Privilege Assignment CWE-284: Improper Access Control •

CVE-2025-2551 – D-Link DIR-618/DIR-605L formSetPortTr access control
https://notcve.org/view.php?id=CVE-2025-2551
20 Mar 2025 — A vulnerability was found in D-Link DIR-618 and DIR-605L 2.02/3.02. It has been classified as problematic. This affects an unknown part of the file /goform/formSetPortTr. The manipulation leads to improper access controls. Access to the local network is required for this attack. • https://lavender-bicycle-a5a.notion.site/D-Link-DIR-605L-formSetPortTr-1b153a41781f809d95c8e39c6c31c348?pvs=4 • CWE-266: Incorrect Privilege Assignment CWE-284: Improper Access Control •

CVE-2025-2550 – D-Link DIR-618/DIR-605L DDNS Service formSetDDNS access control
https://notcve.org/view.php?id=CVE-2025-2550
20 Mar 2025 — A vulnerability was found in D-Link DIR-618 and DIR-605L 2.02/3.02 and classified as problematic. Affected by this issue is some unknown functionality of the file /goform/formSetDDNS of the component DDNS Service. The manipulation leads to improper access controls. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. • https://lavender-bicycle-a5a.notion.site/D-Link-DIR-605L-formSetDDNS-1b153a41781f80feb80bd24afc8f83d5?pvs=4 • CWE-266: Incorrect Privilege Assignment CWE-284: Improper Access Control •

CVE-2025-2549 – D-Link DIR-618/DIR-605L formSetPassword access control
https://notcve.org/view.php?id=CVE-2025-2549
20 Mar 2025 — A vulnerability has been found in D-Link DIR-618 and DIR-605L 2.02/3.02 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /goform/formSetPassword. The manipulation leads to improper access controls. The attack needs to be done within the local network. The exploit has been disclosed to the public and may be used. • https://lavender-bicycle-a5a.notion.site/D-Link-DIR-605L-formSetPassword-1b153a41781f803d8166f9b551b30cd4?pvs=4 • CWE-266: Incorrect Privilege Assignment CWE-284: Improper Access Control •

CVE-2025-2548 – D-Link DIR-618/DIR-605L formSetDomainFilter access control
https://notcve.org/view.php?id=CVE-2025-2548
20 Mar 2025 — A vulnerability, which was classified as problematic, was found in D-Link DIR-618 and DIR-605L 2.02/3.02. Affected is an unknown function of the file /goform/formSetDomainFilter. The manipulation leads to improper access controls. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. • https://lavender-bicycle-a5a.notion.site/D-Link-DIR-605L-formSetDomainFilter-1b153a41781f80498fcdf9d675df9b39?pvs=4 • CWE-266: Incorrect Privilege Assignment CWE-284: Improper Access Control •