4 results (0.010 seconds)

CVSS: 9.0EPSS: 0%CPEs: 2EXPL: 1

An issue was discovered on D-Link DIR-818LW devices with firmware 2.06betab01. There is a command injection in HNAP1 (exploitable with Authentication) via shell metacharacters in the Type field to SetWanSettings. Se detectó un problema en los dispositivos DIR-818LW con firmware versión 2.06betab01 de D-Link. Se presenta una inyección de comando en HNAP1 (explotable con identificación) por medio de metacaracteres de shell en el campo Type a SetWanSettings. • http://www.securityfocus.com/bid/109131 https://github.com/TeamSeri0us/pocs/blob/master/iot/dlink/dir818-4.pdf • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 9.0EPSS: 0%CPEs: 2EXPL: 1

An issue was discovered on D-Link DIR-818LW devices with firmware 2.06betab01. There is a command injection in HNAP1 (exploitable with Authentication) via shell metacharacters in the MTU field to SetWanSettings. Se detectó un problema en los dispositivos DIR-818LW con firmware versión 2.06betab01 de D-Link. Se presenta una inyección de comando en HNAP1 (explotable con identificación) por medio de metacaracteres de shell en el campo MTU en SetWanSettings. • http://www.securityfocus.com/bid/109131 https://github.com/TeamSeri0us/pocs/blob/master/iot/dlink/dir818-3.pdf • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 8.8EPSS: 0%CPEs: 3EXPL: 1

An issue was discovered on D-Link DIR-818LW devices from 2.05.B03 to 2.06B01 BETA. There is a command injection in HNAP1 SetWanSettings via an XML injection of the value of the Gateway key. Se descubrió un error en los dispositivos D-Link DIR-818LW desde 2.05.B03 hasta 2.06B01 BETA, Hay una inyección de comandos en HNAP1 SetWanSettings a través de una inyección XML de los valores de la clave de Gateway • https://github.com/TeamSeri0us/pocs/blob/master/iot/dlink/dir818-2-protected.pdf • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 8.8EPSS: 0%CPEs: 3EXPL: 1

An issue was discovered on D-Link DIR-818LW devices from 2.05.B03 to 2.06B01 BETA. There is a command injection in HNAP1 SetWanSettings via an XML injection of the value of the IPAddress key. Se descubrió un error en los dispositivos D-Link DIR-818LW desde 2.05.B03 hasta 2.06B01 BETA. Hay una inyección de comandos en HNAP1 SetWanSetting mediante una inyección XML de los valor de la clave IPAddress. • https://github.com/TeamSeri0us/pocs/blob/master/iot/dlink/dir818-protected.pdf • CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') •