85 results (0.007 seconds)

CVSS: 7.5EPSS: 0%CPEs: 18EXPL: 0

A stack-based buffer overflow in Fortinet FortiPAM version 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiWeb, FortiAuthenticator, FortiSwitchManager version 7.2.0 through 7.2.3, 7.0.1 through 7.0.3, FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15, 6.2.0 through 6.2.16, 6.0.0 through 6.0.18, FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.15, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specially crafted packets. Un desbordamiento de búfer basado en pila en Fortinet FortiPAM versión 1.2.0, 1.1.0 a 1.1.2, 1.0.0 a 1.0.3, FortiWeb, FortiAuthenticator, FortiSwitchManager versión 7.2.0 a 7.2.3, 7.0.1 a 7.0. 3, FortiOS versión 7.4.0 a 7.4.3, 7.2.0 a 7.2.7, 7.0.0 a 7.0.14, 6.4.0 a 6.4.15, 6.2.0 a 6.2.16, 6.0.0 a 6.0. 18, FortiProxy versión 7.4.0 a 7.4.2, 7.2.0 a 7.2.9, 7.0.0 a 7.0.15, 2.0.0 a 2.0.13, 1.2.0 a 1.2.13, 1.1.0 a 1.1. 6, 1.0.0 a 1.0.7 permite a un atacante ejecutar código o comandos no autorizados a través de paquetes especialmente manipulados. • https://fortiguard.fortinet.com/psirt/FG-IR-24-036 • CWE-121: Stack-based Buffer Overflow •

CVSS: 6.7EPSS: 0%CPEs: 6EXPL: 0

A stack-based buffer overflow in Fortinet FortiOS version 7.4.0 through 7.4.1 and 7.2.0 through 7.2.7 and 7.0.0 through 7.0.12 and 6.4.6 through 6.4.15 and 6.2.9 through 6.2.16 and 6.0.13 through 6.0.18 allows attacker to execute unauthorized code or commands via specially crafted CLI commands. Un desbordamiento de búfer basado en pila en Fortinet FortiOS versión 7.4.0 a 7.4.1 y 7.2.0 a 7.2.7 y 7.0.0 a 7.0.12 y 6.4.6 a 6.4.15 y 6.2.9 a 6.2.16 y Las versiones 6.0.13 a 6.0.18 permiten a un atacante ejecutar código o comandos no autorizados a través de comandos CLI especialmente manipulados. • https://fortiguard.fortinet.com/psirt/FG-IR-23-356 • CWE-121: Stack-based Buffer Overflow •

CVSS: 7.8EPSS: 0%CPEs: 6EXPL: 0

A stack-based buffer overflow in Fortinet FortiOS version 7.4.0 through 7.4.2, 7.2.0 through 7.2.6, 7.0.0 through 7.0.13, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, 6.0 all versions allows attacker to execute unauthorized code or commands via specially crafted commands Un desbordamiento de búfer basado en pila en Fortinet FortiOS versión 7.4.0 a 7.4.2, 7.2.0 a 7.2.6, 7.0.0 a 7.0.13, 6.4.0 a 6.4.14, 6.2.0 a 6.2.15, 6.0 todas las versiones permiten al atacante ejecutar código o comandos no autorizados mediante comandos especialmente manipulados • https://fortiguard.com/psirt/FG-IR-23-460 • CWE-121: Stack-based Buffer Overflow •

CVSS: 6.7EPSS: 0%CPEs: 12EXPL: 0

A use of externally-controlled format string in Fortinet FortiProxy versions 7.2.0 through 7.2.4, 7.0.0 through 7.0.10, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiPAM versions 1.0.0 through 1.0.3, FortiOS versions 7.2.0, 7.0.0 through 7.0.12, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15, 6.0.0 through 6.0.16 allows attacker to execute unauthorized code or commands via specially crafted commands Un uso de cadena de formato controlada externamente en las versiones Fortinet FortiProxy 7.2.0 a 7.2.4, 7.0.0 a 7.0.10, 2.0.0 a 2.0.13, 1.2.0 a 1.2.13, 1.1.0 a 1.1. 6, 1.0.0 a 1.0.7, versiones de FortiPAM 1.0.0 a 1.0.3, versiones de FortiOS 7.2.0, 7.0.0 a 7.0.12, 6.4.0 a 6.4.14, 6.2.0 a 6.2.15, 6.0.0 a 6.0.16 permite al atacante ejecutar código o comandos no autorizados mediante comandos especialmente manipulados • https://fortiguard.com/psirt/FG-IR-23-137 • CWE-134: Use of Externally-Controlled Format String •

CVSS: 7.2EPSS: 0%CPEs: 12EXPL: 0

A use of externally-controlled format string in Fortinet FortiProxy versions 7.2.0 through 7.2.5, 7.0.0 through 7.0.11, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6 FortiPAM versions 1.1.0, 1.0.0 through 1.0.3 FortiOS versions 7.4.0, 7.2.0 through 7.2.5, 7.0.0 through 7.0.13, 6.4.0 through 6.4.14, 6.2.0 through 6.2.15 FortiSwitchManager versions 7.2.0 through 7.2.2, 7.0.0 through 7.0.2 allows attacker to execute unauthorized code or commands via specially crafted cli commands and http requests. Un uso de cadena de formato controlada externamente en Fortinet FortiProxy versiones 7.2.0 a 7.2.5, 7.0.0 a 7.0.11, 2.0.0 a 2.0.13, 1.2.0 a 1.2.13, 1.1.0 a 1.1. 6 Versiones de FortiPAM 1.1.0, 1.0.0 a 1.0.3 Versiones de FortiOS 7.4.0, 7.2.0 a 7.2.5, 7.0.0 a 7.0.13, 6.4.0 a 6.4.14, 6.2.0 a 6.2. 15 Las versiones 7.2.0 a 7.2.2, 7.0.0 a 7.0.2 de FortiSwitchManager permiten a un atacante ejecutar código o comandos no autorizados a través de comandos cli y solicitudes http especialmente manipulados. • https://fortiguard.com/psirt/FG-IR-23-137 • CWE-134: Use of Externally-Controlled Format String •