![](/assets/img/cve_300x82_sin_bg.png)
CVE-2017-12732
https://notcve.org/view.php?id=CVE-2017-12732
05 Oct 2017 — A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution. Se ha descubierto un problema de desbordamiento de búfer basado en pila en GE CIMPLICITY en versiones 1.6.30.144 y anteriores. Un función lee un paquete para indicar la longitud del siguiente paquete. • http://www.securityfocus.com/bid/101174 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-121: Stack-based Buffer Overflow •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2014-2355
https://notcve.org/view.php?id=CVE-2014-2355
17 Jan 2015 — The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file. Los componentes (1) CimView y (2) CimEdit en GE Proficy HMI/SCADA-CIMPLICITY 8.2 y anteriores permiten a atacantes remotos ganar privilegios a través de un fichero de pantalla CIMPLICITY manipulado (también conocido como .CIM). • https://ics-cert.us-cert.gov/advisories/ICSA-14-289-02 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2014-0751 – GE Proficy CIMPLICITY CimWebServer File Upload Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2014-0751
25 Jan 2014 — Directory traversal vulnerability in CimWebServer.exe (aka the WebView component) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted message to TCP port 10212, aka ZDI-CAN-1623. Vulnerabilidad de salto de directorio en CimWebServer.exe (también conocido como el componente WebView) en GE Intelligent Platforms Proficy HMI / SCADA - CIMPLICITY anterior a 8.2 SIM 24 y Proficy P... • http://ics-cert.us-cert.gov/advisories/ICSA-14-023-01 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2014-0750 – GE Proficy CIMPLICITY gefebt.exe File Upload Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2014-0750
25 Jan 2014 — Directory traversal vulnerability in gefebt.exe in the WebView CimWeb components in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY through 8.2 SIM 24, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary code via a crafted HTTP request, aka ZDI-CAN-1622. Vulnerabilidad de recorrido de directorios en gefebt.exe en los componentes WebView CimWeb de GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY hasta 8.2 SIM 24, y Proficy Process Systems with CIMPLICITY, ... • https://packetstorm.news/files/id/125467 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2013-2811
https://notcve.org/view.php?id=CVE-2013-2811
22 Nov 2013 — The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. El driver (1) Catapult DNP3 I/O anterior a la versión 7.2.0.60 y (2) el driver GE Intelligent Platforms Proficy DNP3 I/O anterior a 7.20k, tal y como se usa en DN... • http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01 • CWE-20: Improper Input Validation •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2013-2823
https://notcve.org/view.php?id=CVE-2013-2823
22 Nov 2013 — The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. El driver (1) Catapult DNP3 I/O anterior a la versión 7.2.0.60 y el driver (2) GE Intelligent Platforms Proficy DNP3 I/O anterior a la versió... • http://ics-cert.us-cert.gov/advisories/ICSA-13-297-01 • CWE-20: Improper Input Validation •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2013-2785 – GE Proficy CIMPLICITY CimWebServer Broadcase/Init Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2013-2785
26 Jul 2013 — Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624. Múltiples vulnerabilidades de desbordamiento de búfer en GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY anterior a 8.0 SIM 27, 8.1 anter... • http://ics-cert.us-cert.gov/advisories/ICSA-13-170-01 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2013-0653 – GE Proficy Cimplicity WebView Substitute.bcl Directory Traversal
https://notcve.org/view.php?id=CVE-2013-0653
27 Jan 2013 — Directory traversal vulnerability in substitute.bcl in the WebView CimWeb subsystem in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process Systems with CIMPLICITY, allows remote attackers to read arbitrary files via a crafted packet. Vulnerabilidad de salto de directorio en substitute.bcl en el subsistema WebView CimWeb en GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY v4.01 a la v8.0, y Proficy Process Systems con CIMPLICITY, permite a atacantes remotos le... • https://packetstorm.news/files/id/180783 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2013-0654
https://notcve.org/view.php?id=CVE-2013-0654
27 Jan 2013 — CimWebServer in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary commands or cause a denial of service (daemon crash) via a crafted packet. CimWebServer en GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY v4.01 a la v8.0, y Proficy Process Systems con CIMPLICITY, permite a atacantes remotos ejecutar comandos arbitrarios o causar una denegación de servicio (caída del demonio) a través de ... • http://www.us-cert.gov/control_systems/pdf/ICSA-13-022-02.pdf • CWE-20: Improper Input Validation •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2012-4689
https://notcve.org/view.php?id=CVE-2012-4689
17 Jan 2013 — Integer overflow in CimWebServer.exe in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process Systems with CIMPLICITY, allows remote attackers to cause a denial of service (daemon crash) via a malformed HTTP request. Un desbordamiento de entero en CimWebServer.exe en GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY v4.01 hasta la v8.0, y Proficy Process Systems con CIMPLICITY, permite a atacantes remotos provocar una denegación de servicio (caída del demonio) a... • http://support.ge-ip.com/support/index?page=kbchannel&id=S:KB15153 • CWE-189: Numeric Errors •