4 results (0.001 seconds)

CVSS: 9.0EPSS: 0%CPEs: 12EXPL: 1

Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt. Grandstream serie HT800 versiones de firmware 1.0.17.5 y posteriores, contiene una backdoor en el servicio SSH. Un atacante remoto autenticado puede obtener un root shell cuando responde correctamente una petición de desafío • https://www.tenable.com/security/research/tra-2020-43 https://www.tenable.com/security/research/tra-2020-47 • CWE-326: Inadequate Encryption Strength CWE-489: Active Debug Code •

CVSS: 7.5EPSS: 0%CPEs: 12EXPL: 1

Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field. Grandstream serie HT800 versiones de firmware 1.0.17.5 y posteriores, es vulnerable a un ataque de denegación de servicio contra el servicio TR-069. Un atacante remoto no autenticado puede detener el servicio debido a una desreferencia del puntero NULL en el servicio TR-069. • https://www.tenable.com/security/research/tra-2020-43 https://www.tenable.com/security/research/tra-2020-47 • CWE-476: NULL Pointer Dereference •

CVSS: 7.8EPSS: 0%CPEs: 12EXPL: 1

Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service. Grandstream serie HT800 versiones de firmware 1.0.17.5 y posteriores, es vulnerable a un agotamiento del CPU debido a un bucle infinito en el servicio TR-069. Los atacantes remotos no autenticados pueden activar este caso mediante el envío de un mensaje TCP de un carácter hacia el servicio TR-069 • https://www.tenable.com/security/research/tra-2020-43 https://www.tenable.com/security/research/tra-2020-47 • CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop') •

CVSS: 9.3EPSS: 0%CPEs: 12EXPL: 1

Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message. Grandstream serie HT800 versiones de firmware 1.0.17.5 y posteriores, es susceptible a una vulnerabilidad de inyección de comandos del Sistema Operativo. Los atacantes remotos no autenticados pueden ejecutar comandos arbitrarios como root mediante el diseño de un archivo de configuración especial y enviado a un mensaje SIP diseñado • https://www.tenable.com/security/research/tra-2020-43 https://www.tenable.com/security/research/tra-2020-47 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •