CVSS: 5.4EPSS: 0%CPEs: 1EXPL: 1

07 Mar 2023 — A vulnerability has been found in SourceCodester Health Center Patient Record Management System 1.0 and classified as problematic. This vulnerability affects unknown code of the file birthing_print.php. The manipulation of the argument birth_id leads to cross site scripting. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. • https://github.com/2689469248/bug_report/blob/main/vendors/razormist/Health%20Center%20Patient%20Record%20Management/XSS-1.md • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 9.8EPSS: 0%CPEs: 1EXPL: 1

07 Mar 2023 — A vulnerability, which was classified as critical, was found in SourceCodester Health Center Patient Record Management System 1.0. This affects an unknown part of the file login.php. The manipulation of the argument username leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. • https://github.com/2689469248/bug_report/blob/main/vendors/razormist/Health%20Center%20Patient%20Record%20Management/SQLi-1.md • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 6.1EPSS: 0%CPEs: 1EXPL: 1

05 Mar 2023 — A vulnerability has been found in SourceCodester Health Center Patient Record Management System 1.0 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file hematology_print.php. The manipulation of the argument hem_id leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. • https://github.com/Yuuuhd/bug_report/blob/main/vendors/razormist/Health%20Center%20Patient%20Record%20Management/XSS-1.md • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.1EPSS: 0%CPEs: 1EXPL: 1

02 Mar 2023 — A vulnerability classified as problematic was found in SourceCodester Health Center Patient Record Management System 1.0. This vulnerability affects unknown code of the file admin/fecalysis_form.php. The manipulation of the argument itr_no leads to cross site scripting. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. • https://github.com/Lacer23/bug_report/blob/main/bug_report/razormist/Health%20Center%20Patient%20Record%20Management/XSS-1.md • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •