4 results (0.003 seconds)

CVSS: 7.5EPSS: 0%CPEs: 32EXPL: 0

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function. Existe una vulnerabilidad en la función HCI Modbus TCP incluida en las versiones de producto enumeradas anteriormente. Si HCI Modbus TCP está habilitado y configurado, un atacante podría aprovechar la vulnerabilidad enviando un mensaje especialmente manipulado a la RTU500 a alta velocidad, lo que provocaría que la CMU RTU500 objetivo se reiniciara. • https://publisher.hitachienergy.com/preview?DocumentID=8DBD000111&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') CWE-787: Out-of-bounds Write •

CVSS: 6.1EPSS: 0%CPEs: 32EXPL: 0

A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to user input being improperly sanitized. Existe una vulnerabilidad en el servidor web que afecta a las versiones de productos de RTU500 series que se enumeran a continuación. Un actor malintencionado podría realizar Cross-Site Scripting en el servidor web debido a que la entrada del usuario se sanitizo incorrectamente. • https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176&languageCode=en&Preview=true • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.1EPSS: 0%CPEs: 32EXPL: 0

A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again. Existe una vulnerabilidad en HCI IEC 60870-5-104 que afecta a las versiones de productos RTU500 series que se enumeran a continuación. El diseño de la trama APDU recibida incompleta o incorrecta puede provocar el bloqueo en la capa de enlace. • https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176&languageCode=en&Preview=true • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.1EPSS: 0%CPEs: 32EXPL: 0

A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to an RDT language file being improperly sanitized. Existe una vulnerabilidad en el servidor web que afecta a las versiones de productos RTU500 series que se enumeran a continuación. Un actor malintencionado podría realizar cross-site scripting en el servidor web debido a que un archivo de idioma RDT no se ha sanitizado incorrectamente. • https://publisher.hitachienergy.com/preview?DocumentId=8DBD000176&languageCode=en&Preview=true • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •