CVE-2014-5397 – ICS-CERT Advisory - Schneider Electric Wonderware
https://notcve.org/view.php?id=CVE-2014-5397
28 Aug 2014 — Cross-site scripting (XSS) vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. Vulnerabilidad de XSS en Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 hasta 5.5 permite a atacantes remotos inyectar secuencias de comandos web o HTML arbitrarios a través de vectores no especificados. Timur Yunusov, Ilya Karpov, Sergey Gordeychik, Alexey Osipov, and Dmitr... • http://www.securityfocus.com/bid/69418 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVE-2014-5398 – ICS-CERT Advisory - Schneider Electric Wonderware
https://notcve.org/view.php?id=CVE-2014-5398
28 Aug 2014 — Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to read arbitrary files or cause a denial of service via an XML external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 hasta 5.5 permite a atacantes remotos leer ficheros arbitrarios o causar una denegación de servicio a través de una declaración de entidad externa XML en co... • https://ics-cert.us-cert.gov/advisories/ICSA-14-238-02 • CWE-20: Improper Input Validation •

CVE-2014-5399 – ICS-CERT Advisory - Schneider Electric Wonderware
https://notcve.org/view.php?id=CVE-2014-5399
28 Aug 2014 — SQL injection vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to execute arbitrary SQL commands via unspecified vectors. Vulnerabilidad de inyección SQL en Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 hasta 5.5 permite a atacantes remotos ejecutar comandos SQL arbitrarios a través de vectores no especificados. Timur Yunusov, Ilya Karpov, Sergey Gordeychik, Alexey Osipov, and Dmitry Serebryannikov of the Posit... • http://www.securityfocus.com/bid/69416 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2014-2380 – ICS-CERT Advisory - Schneider Electric Wonderware
https://notcve.org/view.php?id=CVE-2014-2380
28 Aug 2014 — Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file. Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 hasta 5.5 utiliza codificaciones débiles, lo que permite a atacantes remotos obtener información sensible mediante la lectura de un fichero de credenciales. Timur Yunusov, Ilya Karpov, Sergey Gordeychik, Alexey Osipov, and Dmitry Serebryannikov o... • https://ics-cert.us-cert.gov/advisories/ICSA-14-238-02 •

CVE-2014-2381 – ICS-CERT Advisory - Schneider Electric Wonderware
https://notcve.org/view.php?id=CVE-2014-2381
28 Aug 2014 — Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows local users to obtain sensitive information by reading a credential file. Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 hasta 5.5 utiliza codificaciones débiles, lo que permite a usuarios locales obtener información sensible mediante la lectura de un fichero de credenciales. Timur Yunusov, Ilya Karpov, Sergey Gordeychik, Alexey Osipov, and Dmitry Serebryannikov of the ... • https://ics-cert.us-cert.gov/advisories/ICSA-14-238-02 •

CVE-2013-0684
https://notcve.org/view.php?id=CVE-2013-0684
09 May 2013 — SQL injection vulnerability in Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5- Portal, and 5.0- Portal allows remote attackers to execute arbitrary SQL commands via unspecified vectors. Vulnerabilidad de inyección SQL en Invensys Wonderware Information Server (WIS) v4.0 SP1SP2, v4.5- Portal, y v5.0- Portal que permite a atacantes remotos ejecutar código arbitrario SQL a través de vectores sin especificar. • http://ics-cert.us-cert.gov/advisories/ICSA-13-113-01 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVE-2013-0685
https://notcve.org/view.php?id=CVE-2013-0685
09 May 2013 — Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5- Portal, and 5.0- Portal does not restrict unspecified size and amount values, which allows remote attackers to execute arbitrary code or cause a denial of service (resource consumption) via unknown vectors. Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5- Portal, y 5.0- Portal no restringe los valores tamaño sin especificar y cantidad de valores, lo que permite a atacantes remotos causar una denegación de servicios (consumo de recurs... • http://ics-cert.us-cert.gov/advisories/ICSA-13-113-01 • CWE-264: Permissions, Privileges, and Access Controls •

CVE-2013-0686
https://notcve.org/view.php?id=CVE-2013-0686
09 May 2013 — Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5- Portal, and 5.0- Portal allows remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. Invensys Wonderware Information Server (WIS) V4.0 SP1SP1, v4.5- Portal, y v5.0- Portal permite a atacantes remotos leer ficheros ... • http://ics-cert.us-cert.gov/advisories/ICSA-13-113-01 • CWE-20: Improper Input Validation •

CVE-2013-0688
https://notcve.org/view.php?id=CVE-2013-0688
09 May 2013 — Cross-site scripting (XSS) vulnerability in Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5- Portal, and 5.0- Portal allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. Vulnerabilidad de ejecución de secuencias de comandos en sitios cruzados (XSS) en Invensys Wonderware Information Server (WIS) v4.0 SP1SP1, v4.5- Portal, y v5.0- Portal que permite a atacantes remotos inyectar secuencias de comandos web o HTML a través de vectores no especificados. • http://ics-cert.us-cert.gov/advisories/ICSA-13-113-01 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVE-2012-3005
https://notcve.org/view.php?id=CVE-2012-3005
26 Jul 2012 — Untrusted search path vulnerability in Invensys Wonderware InTouch 2012 and earlier, as used in Wonderware Application Server, Wonderware Information Server, Foxboro Control Software, InFusion CE/FE/SCADA, InBatch, and Wonderware Historian, allows local users to gain privileges via a Trojan horse DLL in an unspecified directory. Una vulnerabilidad de ruta de búsqueda no confiable en Invensys Wonderware InTouch 2012 y anteriores, tal como se utiliza en el servidor de aplicaciones Wonderware, Wonderware Infor... • http://www.us-cert.gov/control_systems/pdf/ICSA-12-177-02.pdf •