3 results (0.008 seconds)

CVSS: 8.8EPSS: 83%CPEs: 36EXPL: 0

Arbitrary code execution vulnerability affecting multiple Micro Focus products. 1.) Operation Bridge Manager affecting version: 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, versions 10.6x and 10.1x and older versions. 2.) Application Performance Management affecting versions : 9.51, 9.50 and 9.40 with uCMDB 10.33 CUP 3 3.) Data Center Automation affected version 2019.11 4.) Operations Bridge (containerized) affecting versions: 2019.11, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05, 2018.02, 2017.11 5.) • http://packetstormsecurity.com/files/161182/Micro-Focus-UCMDB-Remote-Code-Execution.html http://packetstormsecurity.com/files/161366/Micro-Focus-Operations-Bridge-Manager-Remote-Code-Execution.html https://softwaresupport.softwaregrp.com/doc/KM03747657 https://softwaresupport.softwaregrp.com/doc/KM03747658 https://softwaresupport.softwaregrp.com/doc/KM03747854 https://softwaresupport.softwaregrp.com/doc/KM03747948 https://softwaresupport.softwaregrp.com/doc/KM03747949 https://softwaresupport.softwaregrp.com/doc/KM03747950 https://soft •

CVSS: 10.0EPSS: 3%CPEs: 8EXPL: 0

Incorrect Authorization vulnerability in Micro Focus Container Deployment Foundation component affects products: - Hybrid Cloud Management. Versions 2018.05 to 2019.11. - ArcSight Investigate. versions 2.4.0, 3.0.0 and 3.1.0. - ArcSight Transformation Hub. versions 3.0.0, 3.1.0, 3.2.0. - ArcSight Interset. version 6.0.0. - ArcSight ESM (when ArcSight Fusion 1.0 is installed). version 7.2.1. - Service Management Automation (SMA). versions 2018.05 to 2020.02 - Operation Bridge Suite (Containerized). Versions 2018.05 to 2020.02. - Network Operation Management. versions 2017.11 to 2019.11. - Data Center Automation Containerized. versions 2018.05 to 2019.11 - Identity Intelligence. versions 1.1.0 and 1.1.1. The vulnerability could be exploited to provide unauthorized access to the Container Deployment Foundation. La vulnerabilidad de la autorización incorrecta en el componente Micro Focus Container Deployment Foundation afecta a los productos: Hybrid Cloud Management. desde la versión 2018.05 hasta 2019.11. - ArcSight Investigate. versiones 2.4.0, 3.0.0 y 3.1.0. - ArcSight Transformation Hub. versiones 3.0.0, 3.1.0, 3.2.0. - ArcSight Interset. versión 6.0.0. - ArcSight ESM (cuando se instala ArcSight Fusion 1.0). versión 7.2.1. - Service Management Automation (SMA). desde la versión 2018.05 hasta 2020.02 - Operation Bridge Suite (Containerized). desde la versión 2018.05 hasta 2020.02. - Network Operation Management. desde la versión 2017.11 hasta 2019.11. - Data Center Automation Containerized. desde la versión 2018.05 hasta 2019.11. • https://softwaresupport.softwaregrp.com/doc/KM03645628 https://softwaresupport.softwaregrp.com/doc/KM03645629 https://softwaresupport.softwaregrp.com/doc/KM03645630 https://softwaresupport.softwaregrp.com/doc/KM03645631 https://softwaresupport.softwaregrp.com/doc/KM03645636 https://softwaresupport.softwaregrp.com/doc/KM03645642 https://support.microfocus.com/kb/doc.php?id=7024637 • CWE-863: Incorrect Authorization •

CVSS: 9.3EPSS: 0%CPEs: 43EXPL: 21

runc through 1.0-rc6, as used in Docker before 18.09.2 and other products, allows attackers to overwrite the host runc binary (and consequently obtain host root access) by leveraging the ability to execute a command as root within one of these types of containers: (1) a new container with an attacker-controlled image, or (2) an existing container, to which the attacker previously had write access, that can be attached with docker exec. This occurs because of file-descriptor mishandling, related to /proc/self/exe. runc, hasta la versión 1.0-rc6, tal y como se emplea en Docker, en versiones anteriores a la 18.09.2 y otros productos, permite que los atacantes sobrescriban el binario del host runc (y, así, obtengan acceso root al host) aprovechando la capacidad para ejecutar un comando como root con uno de estos tipos de contenedores: (1) un nuevo contenedor con una imagen controlada por el atacante o (2) un contenedor existente, para el cual el atacante contaba previamente con acceso de escritura, que puede adjuntarse con docker exec. Esto ocurre debido a la gestión incorrecta del descriptor de archivos; esto está relacionado con /proc/self/exe. A flaw was found in the way runc handled system file descriptors when running containers. A malicious container could use this flaw to overwrite contents of the runc binary and consequently run arbitrary commands on the container host system. • https://github.com/Frichetten/CVE-2019-5736-PoC https://www.exploit-db.com/exploits/46369 https://www.exploit-db.com/exploits/46359 https://github.com/twistlock/RunC-CVE-2019-5736 https://github.com/jas502n/CVE-2019-5736 https://github.com/RyanNgWH/CVE-2019-5736-POC https://github.com/zyriuse75/CVE-2019-5736-PoC https://github.com/likescam/CVE-2019-5736 https://github.com/geropl/CVE-2019-5736 https://github.com/si1ent-le/CVE-2019-5736 https://github.com/ • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') CWE-672: Operation on a Resource after Expiration or Release •