CVE-2021-20593
https://notcve.org/view.php?id=CVE-2021-20593
Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior) and Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) allows a remote authenticated attacker to impersonate administrators to disclose configuration information of the air conditioning system and tamper information (e.g. operation information and configuration of air conditioning system) by exploiting this vulnerability. Una Implementación Incorrecta del Algoritmo de Autenticación en Mitsubishi Electric Air Conditioning System/Centralized Controllers versiones: (G-50A Versiones.2.50 hasta Versiones. 3.35, GB-50A Versiones.2.50 hasta Versiones. 3.35, AG-150A-A Ver.3.20 y anteriores, AG-150A-J Ver.3.20 y anteriores, GB-50ADA-A Versiones.3.20 y anteriores, GB-50ADA-J Versiones.3 .20 y anteriores, EB-50GU-A Versiones 7.09 y anteriores, EB-50GU-J Versiones 7.09 y anteriores, AE-200A Versiones 7.93 y anteriores, AE-200E Versiones 7.93 y anteriores, AE-50A Versiones 7.93 y anteriores, AE-50E Versiones 7.93 y anteriores, EW-50A Versiones 7.93 y anteriores, EW-50E Versiones 7.93 y anteriores, TE-200A Versiones 7.93 y anteriores, TE-50A Versiones 7.93 y anteriores, TW-50A Versiones 7.93 y anteriores, CMS-RMD-J Versiones.1 .30 y anteriores) y los Controladores del Air Conditioning System/Expansion (PAC-YG50ECA Versiones .2.20 y anteriores) permiten a un atacante remoto autenticado hacerse pasar por administrador para divulgar información de configuración del sistema de aire acondicionado e información de manipulación (por ejemplo, información de funcionamiento y configuración del sistema de aire acondicionado) al explotar esta vulnerabilidad • https://jvn.jp/vu/JVNVU96046575/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-004_en.pdf • CWE-287: Improper Authentication •
CVE-2021-20595
https://notcve.org/view.php?id=CVE-2021-20595
Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets. Una vulnerabilidad de restricción inapropiada de referencia de tipo XML External Entity en Mitsubishi Electric Air Conditioning System/Centralized Controllers versiones: (G-50A Ver.3.35 y anteriores, GB-50A Ver.3.35 y anteriores, GB-24A Ver.9.11 y anteriores, AG-150A-A Ver.3.20 y anteriores, AG-150A-J Ver.3.20 y anteriores, GB-50ADA-A Ver.3.20 y anteriores, GB-50ADA-J Ver.3 .20 y anteriores, EB-50GU-A Ver 7.09 y anteriores, EB-50GU-J Ver 7.09 y anteriores, AE-200A Ver 7.93 y anteriores, AE-200E Ver 7.93 y anteriores, AE-50A Ver 7.93 y anteriores, AE-50E Ver 7.93 y anteriores, EW-50A Ver 7.93 y anteriores, EW-50E Ver 7.93 y anteriores, TE-200A Ver 7.93 y anteriores, TE-50A Ver 7.93 y anteriores, TW-50A Ver 7.93 y anteriores, CMS-RMD-J Ver.1 .30 y anteriores), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 y anteriores) y Sistema de Aire Acondicionado/Adaptador BM (BAC-HD150 Ver.2.21 y anteriores) permite a un atacante remoto no autenticado divulgar algunos de los datos del sistema de aire acondicionado o causar una condición de DoS mediante el envío de paquetes especialmente diseñados • https://jvn.jp/vu/JVNVU93086468/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-005_en.pdf • CWE-611: Improper Restriction of XML External Entity Reference •