CVSS: 9.8EPSS: 0%CPEs: 29EXPL: 0

19 May 2022 — Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. Una explotación con éxito de esta vulnerabilidad para múltiples Productos Mitsubishi Electric Factory Automation Engineering Software de varias versiones podría perm... • https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02 • CWE-275: Permission Issues •

CVSS: 9.8EPSS: 1%CPEs: 27EXPL: 0

11 Feb 2022 — Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code. diversos productos de Mitsubishi Electric Factory Automation presentan una vulnerabilidad que permite a un atacante ejecutar código arbitrario • https://jvn.jp/vu/JVNVU90224831 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 9.8EPSS: 0%CPEs: 60EXPL: 0

11 Feb 2022 — Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. diversos productos de software de ingeniería de Mitsubishi Electric Factory Automation presentan una vulnerabilidad de ejecución de código malicioso. Un atacante malicioso podría usar esta vulnerabilidad para obtener información, modificar información y... • https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04 • CWE-276: Incorrect Default Permissions CWE-428: Unquoted Search Path or Element •

CVSS: 5.5EPSS: 0%CPEs: 3EXPL: 0

17 Dec 2021 — Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker. Una vulnerabilidad de desbordamiento de enteros en las versiones 1.606G y anteriores de Mitsubishi Electric GX Works2, en las versiones 2.84N y anteriores de ... • https://jvn.jp/vu/JVNVU93817405/index.html • CWE-191: Integer Underflow (Wrap or Wraparound) •

CVSS: 5.5EPSS: 0%CPEs: 3EXPL: 0

17 Dec 2021 — Out-of-bounds Read vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker. Una vulnerabilidad de lectura fuera de los límites en las versiones 1.606G y anteriores de Mitsubishi Electric GX Works2, en las versiones 2.84N y anteriores... • https://jvn.jp/vu/JVNVU93817405/index.html • CWE-125: Out-of-bounds Read •

CVSS: 7.5EPSS: 0%CPEs: 1EXPL: 0

17 Dec 2021 — Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file. Una vulnerabilidad de Manejo Inapropiado de la Inconsistencia de los Parámetros de Longitud en Mitsubishi Electric GX Works2 versiones 1.606G y anteriores... • https://jvn.jp/vu/JVNVU93019896/index.html •

CVSS: 9.8EPSS: 2%CPEs: 41EXPL: 0

19 Feb 2021 — Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and pr... • https://jvn.jp/vu/JVNVU92330101/index.html • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 9.8EPSS: 1%CPEs: 41EXPL: 0

19 Feb 2021 — Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Vers... • https://jvn.jp/vu/JVNVU92330101/index.html • CWE-787: Out-of-bounds Write •

CVSS: 7.5EPSS: 0%CPEs: 20EXPL: 0

30 Jun 2020 — Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible High-Speed I/O C... • https://jvn.jp/en/vu/JVNVU90307594/index.html • CWE-611: Improper Restriction of XML External Entity Reference •

CVSS: 7.5EPSS: 0%CPEs: 20EXPL: 0

30 Jun 2020 — Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. ... • https://jvn.jp/en/vu/JVNVU90307594/index.html • CWE-400: Uncontrolled Resource Consumption •