CVSS: 9.8EPSS: 0%CPEs: 10EXPL: 0

Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products. Vulnerabilidad de uso de entrada controlada externamente para seleccionar clases o código ("Reflexión insegura") en Mitsubishi Electric Corporation EZSocket versiones 3.0 y posteriores, FR Configurator2 todas las versiones, GT Designer3 Versión1(GOT1000) todas las versiones, GT Designer3 Versión1(GOT2000) todas las versiones , GX Works2 versiones 1.11M y posteriores, GX Works3 todas las versiones, MELSOFT Navigator versiones 1.04E y posteriores, MT Works2 todas las versiones, MX Component versiones 4.00A y posteriores y MX OPC Server DA/UA todas las versiones permiten que un atacante remoto no autenticado ejecute un código malicioso por RPC con una ruta a una librería maliciosa mientras está conectado a los productos. Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products. • https://jvn.jp/vu/JVNVU95103362 https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf • CWE-470: Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') •

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally. Autenticación faltante para vulnerabilidad de función crítica en Mitsubishi Electric Corporation EZSocket versiones 3.0 y posteriores, FR Configurator2 todas las versiones, GT Designer3 Versión1(GOT1000) todas las versiones, GT Designer3 Versión1(GOT2000) todas las versiones, GX Works2 versiones 1.11M y posteriores, GX Works3 todas versiones, MELSOFT Navigator versiones 1.04E y posteriores, MT Works2 todas las versiones, MX Component versiones 4.00A y posteriores y MX OPC Server DA/UA todas las versiones permiten a un atacante remoto no autenticado eludir la autenticación enviando paquetes especialmente manipulados y conectándose a los productos ilegalmente. Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally. • https://jvn.jp/vu/JVNVU95103362 https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf • CWE-306: Missing Authentication for Critical Function •

CVSS: 9.8EPSS: 0%CPEs: 29EXPL: 0

Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. Una explotación con éxito de esta vulnerabilidad para múltiples Productos Mitsubishi Electric Factory Automation Engineering Software de varias versiones podría permitir a un atacante escalar privilegios y ejecutar programas maliciosos, lo que podría causar una condición de denegación de servicio, y permitir que la información sea divulgada, manipulada y/o destruida • https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-02 • CWE-275: Permission Issues •

CVSS: 9.8EPSS: 1%CPEs: 27EXPL: 0

Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code. diversos productos de Mitsubishi Electric Factory Automation presentan una vulnerabilidad que permite a un atacante ejecutar código arbitrario • https://jvn.jp/vu/JVNVU90224831 https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 9.8EPSS: 0%CPEs: 60EXPL: 0

Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. diversos productos de software de ingeniería de Mitsubishi Electric Factory Automation presentan una vulnerabilidad de ejecución de código malicioso. Un atacante malicioso podría usar esta vulnerabilidad para obtener información, modificar información y causar una condición de denegación de servicio • https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-04 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-007_en.pdf • CWE-276: Incorrect Default Permissions CWE-428: Unquoted Search Path or Element •