CVE-2021-20600
https://notcve.org/view.php?id=CVE-2021-20600
Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions "16" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time while the module starting up. System reset is required for recovery. El consumo incontrolado de recursos en el módulo controlador C de la serie MELSEC iQ-R de Mitsubishi Electric R12CCPU-V, versiones de firmware "16" y anteriores, permite que un atacante remoto no autenticado provoque una condición de denegación de servicio (DoS) mediante el envío de un gran número de paquetes en poco tiempo durante el arranque del módulo. Se requiere un reinicio del sistema para la recuperación • https://jvn.jp/vu/JVNVU94914666/index.html https://us-cert.cisa.gov/ics/advisories/icsa-21-280-04 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-015_en.pdf • CWE-400: Uncontrolled Resource Consumption •
CVE-2020-16226 – Mitsubishi Electric Multiple Products
https://notcve.org/view.php?id=CVE-2020-16226
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands. Múltiples productos de Mitsubishi Electric, son vulnerables a suplantaciones de un dispositivo legítimo por parte de un actor malicioso, lo que puede permitir a un atacante ejecutar comandos arbitrarios remotamente This vulnerability allows remote attackers to execute arbitrary code on affected installations of Mitsubishi Electric MELSEC iQ-F. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of ACK packets. When generating ACK packets, the application uses a predictable sequence number. An attacker can leverage this vulnerability to execute arbitrary code in the context of the current process. • https://us-cert.cisa.gov/ics/advisories/icsa-20-245-01 • CWE-342: Predictable Exact Value from Previous Values •
CVE-2020-5531
https://notcve.org/view.php?id=CVE-2020-5531
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors. Mitsubishi Electric MELSEC C Controller Module y MELIPC Series MI5000 MELSEC-Q Series C Controller Module (Q24DHCCPU-V, Q24DHCCPU-VG puerto User Ethernet (CH1, CH2): Primeros 5 dígitos del número de serial 21121 o anterior), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module (R12CCPU-V puerto Ethernet (CH1, CH2): Primeros 2 dígitos del número de serial 11 o anterior, y RD55UP06-V puerto Ethernet: Primeros 2 dígitos del número de serial 08 o anterior), y MELIPC Series MI5000 (MI5122-VW puerto Ethernet (CH1): Primeros 2 dígitos del número de serial 03 o anterior, o la versión de firmware 03 o anterior), permite a atacantes remotos causar una denegación de servicio (DoS) y/o un malware que se ejecuta por medio de vectores no especificados. • https://jvn.jp/en/vu/JVNVU95424547/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf •