6 results (0.011 seconds)

CVSS: 7.5EPSS: 0%CPEs: 4EXPL: 1

A cleartext transmission vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted network sniffing can lead to a disclosure of sensitive information. An attacker can sniff network traffic to trigger this vulnerability. • https://talosintelligence.com/vulnerability_reports/TALOS-2022-1616 https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities • CWE-319: Cleartext Transmission of Sensitive Information •

CVSS: 7.5EPSS: 0%CPEs: 4EXPL: 1

A denial of service vulnerability exists in the web server functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP message header can lead to denial of service. An attacker can send an HTTP request to trigger this vulnerability. • https://talosintelligence.com/vulnerability_reports/TALOS-2022-1618 https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities • CWE-410: Insufficient Resource Pool •

CVSS: 5.4EPSS: 0%CPEs: 4EXPL: 1

A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="switch_contact" • https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619 https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 5.4EPSS: 0%CPEs: 4EXPL: 1

A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description" • https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619 https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 5.4EPSS: 0%CPEs: 4EXPL: 1

A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="webLocationMessage_text" name="webLocationMessage_text" • https://talosintelligence.com/vulnerability_reports/TALOS-2022-1619 https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •