CVSS: 7.5EPSS: 0%CPEs: 4EXPL: 0

The OPC UA Legacy Java Stack before 6f176f2 enables an attacker to block OPC UA server applications via uncontrolled resource consumption so that they can no longer serve client applications. El OPC UA Legacy Java Stack anterior a 6f176f2 permite a un atacante bloquear aplicaciones del servidor OPC UA mediante el consumo incontrolado de recursos para que ya no puedan servir aplicaciones cliente. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Prosys OPC UA Simulation Server. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OpenSecureChannel messages. By sending a large number of requests, an attacker can consume all available resources on the server. • https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2023-32787.pdf https://github.com/OPCFoundation/UA-Java-Legacy https://github.com/OPCFoundation/UA-Java-Legacy/commit/6f176f2b445a27c157f1a32f225accc9ce8873c0 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 8.2EPSS: 0%CPEs: 2EXPL: 0

An XXE vulnerability in the OPC UA Java and .NET Legacy Stack can allow remote attackers to trigger a denial of service. Una vulnerabilidad XEE (XML External Entity) en la pila OPC UA Java y .NET Legacy puede permitir que atacantes remotos desencadenen una denegación de servicio (DoS). • http://www.securityfocus.com/bid/105538 https://opcfoundation-onlineapplications.org/faq/SecurityBulletins/OPC_Foundation_Security_Bulletin_CVE-2018-12585.pdf • CWE-611: Improper Restriction of XML External Entity Reference •