CVSS: 5.3EPSS: 0%CPEs: 36EXPL: 0

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet. IntelliVue Patient Monitors MP Series (incluyendo MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M y (X3/MX100 solo para Rev M) y Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 con software Revisions F.0, G.0 y J.3 tienen una vulnerabilidad que permite que un atacante no autenticado lea memoria desde una dirección del dispositivo escogida por el atacante en la misma subred. • https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 8.3EPSS: 0%CPEs: 36EXPL: 0

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet. IntelliVue Patient Monitors MP Series (incluyendo MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M y (X3/MX100 solo para Rev M) y Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 con software Revisions F.0, G.0 y J.3 tienen una vulnerabilidad que permite que un atacante no autenticado acceda a memoria ("write-what-where") desde una dirección del dispositivo escogida por el atacante en la misma subred. • https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01 • CWE-287: Improper Authentication CWE-787: Out-of-bounds Write •

CVSS: 8.2EPSS: 0%CPEs: 36EXPL: 0

IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow. IntelliVue Patient Monitors MP Series (incluyendo MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M y (X3/MX100 solo para Rev M) y Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 con software en Revisions F.0, G.0 y J.3 tienen una vulnerabilidad que expone un servicio "echo" por el cual un búfer enviado por el atacante a una dirección de dispositivo en la misma subred elegida por el atacante se copia a la pila sin comprobaciones de límites, lo que resulta en un desbordamiento de pila. • https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •