11 results (0.018 seconds)

CVSS: 6.5EPSS: 0%CPEs: 5EXPL: 0

27 Dec 2021 — The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0. El uso de un algoritmo criptográfico roto o arriesgado es un riesgo no necesario que puede resultar en una exposición de información confidencial, que afecta a las comunicaciones entre Patient Information Center iX (PIC i... • https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02 • CWE-327: Use of a Broken or Risky Cryptographic Algorithm •

CVSS: 6.5EPSS: 0%CPEs: 2EXPL: 0

27 Dec 2021 — Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. Patient Information Center iX (PIC iX) Versiones C.02 y C.03, recibe entradas o datos, pero no comprueba o comprueba incorrectamente que la entrada presenta las propiedades necesarias para procesar los datos de forma segura y correcta • https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02 • CWE-20: Improper Input Validation •

CVSS: 6.1EPSS: 0%CPEs: 3EXPL: 0

27 Dec 2021 — The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03. El uso de una clave criptográfica embebida aumenta significativamente la posibilidad de que los datos encriptados puedan ser recuperados de Patient Information Center iX (PIC iX) Versiones B.02, C.02 y C.03 • https://www.cisa.gov/uscert/ics/advisories/icsma-21-322-02 • CWE-321: Use of Hard-coded Cryptographic Key •

CVSS: 6.8EPSS: 0%CPEs: 3EXPL: 0

11 Sep 2020 — In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges. Patient Information Center iX (PICiX) Versiones B.02, C.02, C.03, PerformanceBridge Focal Poin... • https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 • CWE-668: Exposure of Resource to Wrong Sphere •

CVSS: 4.3EPSS: 0%CPEs: 4EXPL: 0

11 Sep 2020 — In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling. Patient Information Center iX (PICiX) Versiones B.02, C.02, C.03, PerformanceBridge Focal... • https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 • CWE-1286: Improper Validation of Syntactic Correctness of Input •

CVSS: 6.5EPSS: 0%CPEs: 26EXPL: 0

11 Sep 2020 — In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart. Patient Information Center iX (PICiX) Versiones B.02, C.02, C.03, PerformanceBridge Focal Point Versión A.01, Monitores de paciente... • https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 • CWE-20: Improper Input Validation •

CVSS: 6.5EPSS: 0%CPEs: 2EXPL: 0

11 Sep 2020 — In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart. Patient Information Center iX (PICiX) Versiones B.02, C.02, C.03, PerformanceBridge Focal Point Versión A.01, monitores de paciente IntelliVue MX100, MX400-MX850 y MP2-MP90 Versiones N y anteriores, IntelliV... • https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 • CWE-130: Improper Handling of Length Parameter Inconsistency •

CVSS: 6.4EPSS: 0%CPEs: 26EXPL: 0

11 Sep 2020 — In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate. Patient Information Center iX (PICiX) Versiones B.02, C.02, C.03, PerformanceBridge Focal Point Versión A.01, Monitores de paciente IntelliVue MX100, MX400-MX... • https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 • CWE-299: Improper Check for Certificate Revocation •

CVSS: 8.8EPSS: 0%CPEs: 4EXPL: 0

11 Sep 2020 — In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct. Patient Information Center iX (PICiX) Versiones B.02, C.02, C.03, PerformanceBridge Focal Point Versión A.01, Monitores de paciente IntelliVue MX100, MX400-MX850 y MP2-MP90 Versiones N y anteriores, IntelliVue X3 y X2 Versiones N y anteriores. Cuando un actor afirma ten... • https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 • CWE-287: Improper Authentication •

CVSS: 5.8EPSS: 0%CPEs: 3EXPL: 0

11 Sep 2020 — In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software. Patient Information Center iX (PICiX) Versiones B.02, C.02, C.03, PerformanceBridge Focal Point Versión A.01, Monitores de paciente IntelliVue MX100, MX400-MX850 y MP2-MP90 Versiones N y anteriores, ... • https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 • CWE-1236: Improper Neutralization of Formula Elements in a CSV File •