CVE-2023-46143 – Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC
https://notcve.org/view.php?id=CVE-2023-46143
Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC. La vulnerabilidad de descarga de código sin verificación de integridad en los PLC de la línea clásica de PHOENIX CONTACT permite que un atacante remoto no autenticado modifique algunas o todas las aplicaciones en un PLC. • https://cert.vde.com/en/advisories/VDE-2023-057 • CWE-494: Download of Code Without Integrity Check •
CVE-2023-46141 – Phoenix Contact: Automation Worx and classic line controllers prone to Incorrect Permission Assignment for Critical Resource
https://notcve.org/view.php?id=CVE-2023-46141
Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device. La asignación de permisos incorrecta para una vulnerabilidad de recursos críticos en varios productos de la línea clásica de PHOENIX CONTACT permite que un atacante remoto no autenticado obtenga acceso completo al dispositivo afectado. • https://cert.vde.com/en/advisories/VDE-2023-055 • CWE-732: Incorrect Permission Assignment for Critical Resource •
CVE-2022-31800 – Insufficient Verification of Data Vulnerability in PHOENIX CONTACT classic line industrial controllers
https://notcve.org/view.php?id=CVE-2022-31800
An unauthenticated, remote attacker could upload malicious logic to devices based on ProConOS/ProConOS eCLR in order to gain full control over the device. Un atacante remoto no autenticado podría cargar lógica maliciosa en los dispositivos basados en ProConOS/ProConOS eCLR para conseguir el control total del dispositivo • https://cert.vde.com/en/advisories/VDE-2022-025 • CWE-345: Insufficient Verification of Data Authenticity •
CVE-2021-33541 – Phoenix Contact: ILC1x Industrial controllers affected by Denial-of-Service vulnerability
https://notcve.org/view.php?id=CVE-2021-33541
Phoenix Contact Classic Line Controllers ILC1x0 and ILC1x1 in all versions/variants are affected by a Denial-of-Service vulnerability. The communication protocols and device access do not feature authentication measures. Remote attackers can use specially crafted IP packets to cause a denial of service on the PLC's network communication module. A successful attack stops all network communication. To restore the network connectivity the device needs to be restarted. • https://cert.vde.com/en-us/advisories/vde-2021-019 • CWE-770: Allocation of Resources Without Limits or Throttling •