17 results (0.066 seconds)

CVSS: 10.0EPSS: 0%CPEs: 1EXPL: 0

30 Mar 2023 — Rapid7 Nexpose versions 6.6.186 and below suffer from a forced browsing vulnerability. This vulnerability allows an attacker to manipulate URLs to forcefully browse to and access administrative pages. This vulnerability is fixed in version 6.6.187. • https://docs.rapid7.com/release-notes/nexpose/20230329 • CWE-425: Direct Request ('Forced Browsing') •

CVSS: 6.8EPSS: 0%CPEs: 2EXPL: 1

07 Dec 2022 — Rapid7 Nexpose and InsightVM versions prior to 6.6.172 failed to reliably validate the authenticity of update contents. This failure could allow an attacker to provide a malicious update and alter the functionality of Rapid7 Nexpose. The attacker would need some pre-existing mechanism to provide a malicious update, either through a social engineering effort, privileged access to replace downloaded updates in transit, or by performing an Attacker-in-the-Middle attack on the update service itself. Las version... • https://docs.rapid7.com/release-notes/insightvm/20221207 • CWE-494: Download of Code Without Integrity Check •

CVSS: 6.1EPSS: 0%CPEs: 1EXPL: 0

17 Mar 2022 — Rapid7 Nexpose versions 6.6.129 and earlier suffer from a reflected cross site scripting vulnerability, within the shared scan configuration component of the tool. With this vulnerability an attacker could pass literal values as the test credentials, providing the opportunity for a potential XSS attack. This issue is fixed in Rapid7 Nexpose version 6.6.130. Rapid7 Nexpose versiones 6.6.129 y anteriores, sufren una vulnerabilidad de tipo cross site scripting reflejada, dentro del componente de configuración ... • https://docs.rapid7.com/release-notes/nexpose/20220309 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 8.8EPSS: 0%CPEs: 1EXPL: 0

17 Mar 2022 — Rapid7 Nexpose versions 6.6.93 and earlier are susceptible to an SQL Injection vulnerability, whereby valid search operators are not defined. This lack of validation can allow a logged-in, authenticated attacker to manipulate the "ANY" and "OR" operators in the SearchCriteria and inject SQL code. This issue was fixed in Rapid7 Nexpose version 6.6.129. Las versiones 6.6.93 y anteriores de Rapid7 Nexpose son susceptibles de una vulnerabilidad de inyección SQL, por la que no se definen operadores de búsqueda v... • https://docs.rapid7.com/release-notes/nexpose/20220302 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 5.3EPSS: 0%CPEs: 1EXPL: 0

22 Nov 2021 — Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user Rapid7 Nexpose versiones anteriores a 6.6.114, sufren un problema de exposición de información por el que, cuando la sesión del usuario ha finalizado por inactividad, un atacante puede usar la funcionalidad in... • https://docs.rapid7.com/release-notes/nexpose/20211117 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 5.5EPSS: 0%CPEs: 1EXPL: 0

19 Aug 2021 — Rapid7 Nexpose version 6.6.95 and earlier allows authenticated users of the Security Console to view and edit any ticket in the legacy ticketing feature, regardless of the assignment of the ticket. This issue was resolved in version 6.6.96, released on August 4, 2021. Rapid7 Nexpose versiones 6.6.95 y anteriores, permiten a usuarios autenticados de la Consola de Seguridad visualizar y editar cualquier ticket en la funcionalidad legacy ticketing, independientemente de la asignación del ticket. Este problema ... • https://docs.rapid7.com/release-notes/nexpose/20210804 • CWE-306: Missing Authentication for Critical Function •

CVSS: 6.1EPSS: 0%CPEs: 1EXPL: 0

16 Jun 2021 — Rapid7 Nexpose is vulnerable to a non-persistent cross-site scripting vulnerability affecting the Security Console's Filtered Asset Search feature. A specific search criterion and operator combination in Filtered Asset Search could have allowed a user to pass code through the provided search field. This issue affects version 6.6.80 and prior, and is fixed in 6.6.81. If your Security Console currently falls on or within this affected version range, ensure that you update your Security Console to the latest v... • https://docs.rapid7.com/release-notes/nexpose/20210505 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 8.1EPSS: 0%CPEs: 1EXPL: 0

14 Oct 2020 — A SQL Injection issue in Rapid7 Nexpose version prior to 6.6.49 that may have allowed an authenticated user with a low permission level to access resources & make changes they should not have been able to access. Un problema de inyección SQL en Rapid7 Nexpose versiones anteriores a 6.6.49, que puede haber permitido a un usuario autenticado con un nivel de permiso bajo acceder a recursos y realizar cambios a los que no debería haber sido capaz de acceder • https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.49 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 6.8EPSS: 0%CPEs: 1EXPL: 0

03 Sep 2020 — Rapid7 Nexpose installer version prior to 6.6.40 contains an Unquoted Search Path which may allow an attacker on the local machine to insert an arbitrary file into the executable path. This issue affects: Rapid7 Nexpose versions prior to 6.6.40. El instalador de Rapid7 Nexpose versiones anteriores a 6.6.40, contiene una Ruta de Búsqueda Sin Comillas que puede permitir a un atacante en la máquina local insertar un archivo arbitrario en la ruta ejecutable. Este problema afecta a: Rapid7 Nexpose versiones... • https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40 • CWE-428: Unquoted Search Path or Element •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

03 Sep 2020 — In Rapid7 Nexpose installer versions prior to 6.6.40, the Nexpose installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during a Security Console installation and any arbitrary code executable using the same file name. En el instalador de Rapid7 Nexpose versiones anteriores a 6.6.40, el instalador de Nexpose llama un ejecutable que puede ser colocad... • https://help.rapid7.com/insightvm/en-us/release-notes/index.html?pid=6.6.40 • CWE-94: Improper Control of Generation of Code ('Code Injection') •