CVE-2022-46670 – Rockwell Automation MicroLogix 1100 & 1400 Vulnerable to Cross-Site Scripting Attack
https://notcve.org/view.php?id=CVE-2022-46670
16 Dec 2022 — Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. Un investigador de seguridad d... • https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137679 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVE-2020-6111
https://notcve.org/view.php?id=CVE-2020-6111
03 Dec 2020 — An exploitable denial-of-service vulnerability exists in the IPv4 functionality of Allen-Bradley MicroLogix 1100 Programmable Logic Controller Systems Series B FRN 16.000, Series B FRN 15.002, Series B FRN 15.000, Series B FRN 14.000, Series B FRN 13.000, Series B FRN 12.000, Series B FRN 11.000 and Series B FRN 10.000. A specially crafted packet can cause a major error, resulting in a denial of service. An attacker can send a malicious packet to trigger this vulnerability. Se presenta una vulnerabilidad ex... • https://talosintelligence.com/vulnerability_reports/TALOS-2020-1057 • CWE-189: Numeric Errors •

CVE-2020-6984
https://notcve.org/view.php?id=CVE-2020-6984
16 Mar 2020 — Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable. Rockwell Automation MicroLogix 1400 Controllers Series B versiones v21.001 y anteriores, Series A, todas las versiones, MicroLogix 1100 Controller, todas las versiones, RSLogix 500 Software versiones v12.001 y anteriores. La función cripto... • https://www.us-cert.gov/ics/advisories/icsa-20-070-06 • CWE-327: Use of a Broken or Risky Cryptographic Algorithm •

CVE-2020-6990
https://notcve.org/view.php?id=CVE-2020-6990
16 Mar 2020 — Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller. Rockwell Automation MicroLog... • https://www.us-cert.gov/ics/advisories/icsa-20-070-06 • CWE-321: Use of Hard-coded Cryptographic Key CWE-798: Use of Hard-coded Credentials •

CVE-2020-6988
https://notcve.org/view.php?id=CVE-2020-6988
16 Mar 2020 — Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, ... • https://www.us-cert.gov/ics/advisories/icsa-20-070-06 • CWE-287: Improper Authentication CWE-603: Use of Client-Side Authentication •

CVE-2020-6980
https://notcve.org/view.php?id=CVE-2020-6980
16 Mar 2020 — Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext. Rockwell Automation MicroLogix 1400 Controllers Series B versiones v21.001 y anteriores, Series ... • https://www.us-cert.gov/ics/advisories/icsa-20-070-06 • CWE-312: Cleartext Storage of Sensitive Information •

CVE-2019-10955
https://notcve.org/view.php?id=CVE-2019-10955
25 Apr 2019 — In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a malicious site that coul... • https://ics-cert.us-cert.gov/advisories/ICSA-19-113-01 • CWE-601: URL Redirection to Untrusted Site ('Open Redirect') •