CVE-2023-2072 – Rockwell Automation PowerMonitor 1000 Cross-Site Scripting Vulnerability
https://notcve.org/view.php?id=CVE-2023-2072
The Rockwell Automation PowerMonitor 1000 contains stored cross-site scripting vulnerabilities within the web page of the product. The vulnerable pages do not require privileges to access and can be injected with code by an attacker which could be used to leverage an attack on an authenticated user resulting in remote code execution and potentially the complete loss of confidentiality, integrity, and availability of the product. • https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139761 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-787: Out-of-bounds Write •
CVE-2018-19615
https://notcve.org/view.php?id=CVE-2018-19615
Rockwell Automation Allen-Bradley PowerMonitor 1000 all versions. A remote attacker could inject arbitrary code into a targeted userâs web browser to gain access to the affected device. Rockwell Automation Allen-Bradley PowerMonitor 1000 todas las versiones. Un atacante remoto podrÃa inyectar código arbitrario en el navegador web de un usuario objetivo para obtener acceso al dispositivo afectado • http://packetstormsecurity.com/files/150600/Rockwell-Automation-Allen-Bradley-PowerMonitor-1000-XSS.html http://www.securityfocus.com/bid/106333 http://www.securityfocus.com/bid/108538 https://ics-cert.us-cert.gov/advisories/ICSA-19-050-04 https://www.exploit-db.com/exploits/45928 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •
CVE-2018-19616 – Rockwell Automation Allen-Bradley PowerMonitor 1000 - Incorrect Access Control Authentication Bypass
https://notcve.org/view.php?id=CVE-2018-19616
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element. Se ha descubierto un problema en Rockwell Automation Allen-Bradley PowerMonitor 1000. Un usuario autenticado puede añadir/editar/eliminar administradores debido a que el control de acceso se implementa del lado del cliente mediante un atributo deshabilitado para un elemento BUTTON. Rockwell Automation Allen-Bradley PowerMonitor 1000 suffers from an incorrect access control that can allow for authentication bypass. • https://www.exploit-db.com/exploits/45937 http://packetstormsecurity.com/files/150619/Rockwell-Automation-Allen-Bradley-PowerMonitor-1000-Authentication-Bypass.html http://www.securityfocus.com/bid/106333 http://www.securityfocus.com/bid/108538 https://ics-cert.us-cert.gov/advisories/ICSA-19-050-04 • CWE-287: Improper Authentication •