CVE-2021-22681
https://notcve.org/view.php?id=CVE-2021-22681
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores, y RSLogix 5000 versiones 16 hasta 20, usan una clave para verificar que los controladores Logix se estén comunicando con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores y RSLogix 5000: Versiones 16 hasta 20, son vulnerables porque un atacante no autenticado podría pasar por alto este mecanismo de comprobación y autenticarse con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550 , 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800 • https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03 • CWE-522: Insufficiently Protected Credentials •
CVE-2016-9343
https://notcve.org/view.php?id=CVE-2016-9343
An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 (excluding all firmware versions prior to FRN 16.00, which are not affected). By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a stack-based buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service. Ha sido descubierto un problema en Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 a 21.00 (excluyendo todas las versiones de firmware anteriores a FRN 16.00, que no se ven afectadas). Al enviar un paquete de protocolo industrial común (CIP) malformado, un atacante puede realizar un desbordamiento de búfer basado en pila y ejecutar código en el controlador o iniciar un fallo irrecuperable que da como resultado una denegación de servicio. • http://www.securityfocus.com/bid/95304 https://ics-cert.us-cert.gov/advisories/ICSA-16-343-05 • CWE-787: Out-of-bounds Write •
CVE-2014-0755
https://notcve.org/view.php?id=CVE-2014-0755
Rockwell Automation RSLogix 5000 7 through 20.01, and 21.0, does not properly implement password protection for .ACD files (aka project files), which allows local users to obtain sensitive information or modify data via unspecified vectors. Rockwell Automation RSLogix 5000 7 hasta 20.01 y 21.0, no implementa debidamente la protección por contraseña de archivos .ACD (también conocidos como archivos de proyecto), lo cual permite a usuarios locales obtener información sensible o modificar datos a través de vectores no especificados. • http://ics-cert.us-cert.gov/advisories/ICSA-14-021-01 http://osvdb.org/102858 http://www.securityfocus.com/bid/65337 https://exchange.xforce.ibmcloud.com/vulnerabilities/90981 • CWE-255: Credentials Management Errors •
CVE-2012-0222
https://notcve.org/view.php?id=CVE-2012-0222
The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet. El servicio FactoryTalk (FT) RNADiagReceiver en Rockwell Automation Allen-Bradley FactoryTalk CPR9 hasta SR5 y RSLogix 5000 17 hasta 20 permite a atacantes remotos provocar una denegación de servicio (lectura fuera del límite) a través de un paquete manipulado. • http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937 http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •
CVE-2012-0221 – Rockwell Automation FactoryTalk Activation Server - Multiple Denial of Service Vulnerabilities
https://notcve.org/view.php?id=CVE-2012-0221
The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet. El servicio FactoryTalk (FT) RNADiagReceiver en Rockwell Automation Allen-Bradley FactoryTalk CPR9 hasta SR5 y RSLogix 5000 17 hasta 20 no gestiona de forma adecuada el valor de retorno de una función específica, lo que permite a atacantes remotos provocar una denegación de servicio (corte de servicio) a través de un paquete manipulado. • https://www.exploit-db.com/exploits/36570 http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937 http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf • CWE-20: Improper Input Validation •