2 results (0.002 seconds)

CVSS: 8.2EPSS: 0%CPEs: 7EXPL: 0

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. Productos que usan EDS Subsystem: versión 28.0.1 y anteriores (software FactoryTalk Linx (anteriormente llamado RSLinx Enterprise): versiones 6.00, 6.10 y 6.11, RSLinx Classic: versión 4.11.00 y anteriores, software RSNetWorx: versión 28.00.00 y anteriores, software Studio 5000 Logix Designer: versión 32 y anteriores) son vulnerables. El EDS Subsystem no proporciona un saneamiento de entrada adecuado, lo que puede permitir a un atacante diseñar archivos EDS especializados para inyectar consultas SQL y manipular la base de datos que almacena los archivos EDS. Esto puede conllevar a condiciones de denegación de servicio. • https://www.us-cert.gov/ics/advisories/icsa-20-140-01 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 5.5EPSS: 0%CPEs: 7EXPL: 0

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions. Productos que usan EDS Subsystem: versión 28.0.1 y anteriores (software FactoryTalk Linx (anteriormente llamado RSLinx Enterprise): versiones 6.00, 6.10 y 6.11, RSLinx Classic: versión 4.11.00 y anteriores, software RSNetWorx: versión 28.00.00 y anteriores , software Studio 5000 Logix Designer: versión 32 y anteriores), es vulnerable. Se presenta una vulnerabilidad de corrupción de memoria en el algoritmo que coincide con los corchetes en el subsistema EDS. • https://www.us-cert.gov/ics/advisories/icsa-20-140-01 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •