4 results (0.004 seconds)

CVSS: 9.8EPSS: 0%CPEs: 20EXPL: 0

03 Mar 2021 — Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an un... • https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03 • CWE-522: Insufficiently Protected Credentials •

CVSS: 4.3EPSS: 0%CPEs: 3EXPL: 0

09 Jul 2020 — Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program. Rockwell Automation Logix Designer Studio 5000 Versiones 32.00, 32.01 y 32.02, es susceptible a una vulnerabilidad de tipo xml external entity (XXE), que puede permitir a un atacante visualizar nombres de host u otros recursos del programa This vulnerability allows remote attackers to discl... • https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02 • CWE-611: Improper Restriction of XML External Entity Reference •

CVSS: 8.2EPSS: 0%CPEs: 7EXPL: 0

20 May 2020 — Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files.... • https://www.us-cert.gov/ics/advisories/icsa-20-140-01 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 5.5EPSS: 0%CPEs: 7EXPL: 0

19 May 2020 — Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser CO... • https://www.us-cert.gov/ics/advisories/icsa-20-140-01 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •