7 results (0.004 seconds)

CVSS: 9.8EPSS: 0%CPEs: 12EXPL: 0

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface. This vulnerability allows remote attackers to bypass authentication on affected installations of Schneider Electric APC Easy UPS Online. Authentication is not required to exploit this vulnerability. The specific flaw exists within the updateManagerPassword function. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to bypass authentication on the system. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf • CWE-306: Missing Authentication for Critical Function •

CVSS: 9.8EPSS: 0%CPEs: 12EXPL: 0

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric APC Easy UPS Online. Authentication is not required to exploit this vulnerability. The specific flaw exists within the getMacAddressByIP function. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 7.5EPSS: 0%CPEs: 12EXPL: 0

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Schneider Electric APC Easy UPS Online. Authentication is not required to exploit this vulnerability. The specific flaw exists within the SocketService module, which listens on UDP port 41222 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf • CWE-306: Missing Authentication for Critical Function •

CVSS: 9.8EPSS: 0%CPEs: 22EXPL: 0

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric APC Easy UPS Online. Authentication is not required to exploit this vulnerability. The specific flaw exists within the UpLoadAction class. When parsing the filename parameter, the process does not properly validate user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. • https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf • CWE-434: Unrestricted Upload of File with Dangerous Type •

CVSS: 7.8EPSS: 0%CPEs: 22EXPL: 0

A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric APC Easy UPS Online. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the product installer. The product sets incorrect permissions on folders. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. • https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf • CWE-732: Incorrect Permission Assignment for Critical Resource •