CVSS: 7.5EPSS: 0%CPEs: 82EXPL: 0

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-221-04-Modicon_Controllers_Ethernet_Modules_Security_Notification.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 7.5EPSS: 0%CPEs: 28EXPL: 0

A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100 (H), BMXNOE0110 (H), BMXNOR0200H RTU(BMXNOE* all versions)(BMXNOR* versions prior to v1.7 IR24) Existe una vulnerabilidad CWE-269: Gestión de privilegios inadecuada que podría provocar una Denegación de Servicio (DoS) de la comunicación Ethernet del controlador al enviar una solicitud específica a través de SNMP. Productos afectados: CPU Modicon M340 (versiones BMXP34* anteriores a V3.40), módulos de comunicación Ethernet Modicon M340 X80: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOR0200H RTU (BMXNOE* todas las versiones) (versiones BMXNOR* anteriores a v1. 7IR24) • https://www.se.com/us/en/download/document/SEVD-2022-102-02 • CWE-269: Improper Privilege Management •

CVSS: 9.8EPSS: 0%CPEs: 70EXPL: 0

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior). Una CWE-640: Se presenta una vulnerabilidad de Mecanismo de Recuperación de Contraseñas Débiles para Contraseñas Olvidadas que podría causar un acceso no autorizado en modo de lectura y escritura al controlador cuando es comunicado a través de Modbus. Productos afectados: EcoStruxure Control Expert, incluidas todas las versiones de Unity Pro (antiguo nombre de EcoStruxure Control Expert) (V15.0 SP1 y anteriores), EcoStruxure Process Expert, incluidas todas las versiones de EcoStruxure Hybrid DCS (antiguo nombre de EcoStruxure Process Expert) (V2021 y anteriores), Modicon M340 CPU (números de pieza BMXP34*) (V3.40 y anteriores), Modicon M580 CPU (números de pieza BMEP* y BMEH*) (V3.20 y anteriores) • https://www.se.com/us/en/download/document/SEVD-2022-221-01 • CWE-640: Weak Password Recovery Mechanism for Forgotten Password •

CVSS: 5.3EPSS: 0%CPEs: 38EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause denial of HTTP and FTP services when a series of specially crafted requests is sent to the controller over HTTP. Una CWE-754: Se presenta una vulnerabilidad de Comprobación Inapropiada de Condiciones Inusuales o Excepcionales en el Servidor Web en Modicon M340, Legacy Offers Modicon Quantum y Modicon Premium y Módulos de Comunicación asociados (consulte la notificación de seguridad para las versiones afectadas), que podría causar una denegación de servicios HTTP y FTP cuando una serie de peticiones especialmente diseñadas a través de HTTP son enviadas hacia el controlador • https://www.se.com/ww/en/download/document/SEVD-2020-343-06 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 32EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. Una CWE-754: Se presenta una vulnerabilidad de Comprobación Inapropiada de Condiciones Inusuales o Excepcionales en Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (consulte las notificaciones de seguridad para las versiones afectadas), que podría causar una denegación de servicio cuando una petición Read Physical Memory especialmente diseñada a través de Modbus es enviada hacia el controlador • https://www.se.com/ww/en/download/document/SEVD-2020-343-08 • CWE-754: Improper Check for Unusual or Exceptional Conditions •