CVE-2023-2161
https://notcve.org/view.php?id=CVE-2023-2161
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-129-01.pdf • CWE-611: Improper Restriction of XML External Entity Reference •
CVE-2015-1014
https://notcve.org/view.php?id=CVE-2015-1014
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version. Una explotación exitosa de estas vulnerabilidades requiere que el usuario local suba un archivo DLL manipulado en el directorio de sistemas en los servidores que ejecutan Schneider Electric OFS v3.5 con la versión v7.40 de SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 con la versión v7.30 de Vijeo Citect/CitectSCADA y OFS v3.5 con la versiónv7.20 de Vijeo Citect/CitectSCADA. Si la aplicación intenta abrir ese archivo, podría cerrarse inesperadamente o permitir al atacante ejecutar código arbitrario. • https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01 • CWE-427: Uncontrolled Search Path Element •
CVE-2014-0789
https://notcve.org/view.php?id=CVE-2014-0789
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions. Múltiples desbordamientos de buffer en el control OPC Automation 2.0 Server Object ActiveX en Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 y anteriores, TLXCDSTOFS33 3.5 y anteriores, TLXCDLUOFS33 3.5 y anteriores, TLXCDLTOFS33 3.5 y anteriores y TLXCDLFOFS33 3.5 y anteriores permiten a atacantes remotos causar una denegación de servicio a través de argumentos largos hacia funciones no especificadas. • http://ics-cert.us-cert.gov/advisories/ICSA-14-093-01 http://www.schneider-electric.com/corporate/en/support/cybersecurity/viewer-news.page?c_filepath=/templatedata/Content/News/data/en/local/cybersecurity/general_information/2014/03/20140325_vulnerability_disclosure_opc_factory_server.xml • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •
CVE-2013-0662 – SEIG Modbus 3.4 - Denial of Service (PoC)
https://notcve.org/view.php?id=CVE-2013-0662
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. Múltiples desbordamientos de buffer basado en pila en ModbusDrv.exe en Schneider Electric Modbus Serial Driver 1.10 hasta 3.2 permiten a atacantes remotos ejecutar código arbitrario a través de un valor de tamaño de buffer grande en Modbus Application Header. SEIG Modbus version 3.4 suffers from a remote code execution vulnerability. • https://www.exploit-db.com/exploits/45219 https://www.exploit-db.com/exploits/45220 http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01 http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01 http://www.securityfocus.com/bid/66500 • CWE-787: Out-of-bounds Write •
CVE-2014-0774 – Schneider Electric OPC Factory Server OFS Client Stack Buffer Overflow Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2014-0774
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file. Desbordamiento de buffer basado en pila en el cliente C++ de ejemplo en Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35 y TLXCDLFOFS33 - 3.35 permite a usuarios locales ganar privilegios a través de vectores involucrando un archivo de configuración malformado. This vulnerability allows attackers to execute arbitrary code on vulnerable installations of Schneider Electric OFS Client. User interaction is required to exploit this vulnerability in that the target must load a malicious file. The specific flaw exists within the parsing of the configuration file. A crafted configuration file will result in an exploitable stack buffer overflow. • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01 http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02 http://www.securityfocus.com/bid/65871 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •