4 results (0.005 seconds)

CVSS: 5.5EPSS: 0%CPEs: 2EXPL: 0

16 May 2023 — A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user. A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-129-01.pdf • CWE-611: Improper Restriction of XML External Entity Reference •

CVSS: 7.3EPSS: 0%CPEs: 7EXPL: 0

25 Mar 2019 — A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable... • https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01 • CWE-427: Uncontrolled Search Path Element •

CVSS: 9.8EPSS: 63%CPEs: 21EXPL: 4

28 Mar 2014 — Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. Múltiples desbordamientos de buffer basado en pila en ModbusDrv.exe en Schneider Electric Modbus Serial Driver 1.10 hasta 3.2 permiten a atacantes remotos ejecutar código arbitrario a través de un valor de tamaño de buffer grande en Modbus Application Header. SEIG Modbus version 3.4 su... • https://packetstorm.news/files/id/148995 • CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 1%CPEs: 6EXPL: 0

04 Nov 2011 — Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter. Un desbordamiento de búfer en el controlador de dispositivo UNITELWAY Windows, tal y como se utiliza en Schneider Electric Unity P... • http://secunia.com/advisories/46534 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •