CVE-2024-46887
https://notcve.org/view.php?id=CVE-2024-46887
08 Oct 2024 — The web server of affected devices do not properly authenticate user request to the '/ClientArea/RuntimeInfoData.mwsl' endpoint. This could allow an unauthenticated remote attacker to gain knowledge about current actual and configured maximum cycle times as well as about configured maximum communication load. • https://cert-portal.siemens.com/productcert/html/ssa-054046.html • CWE-288: Authentication Bypass Using an Alternate Path or Channel CWE-862: Missing Authorization •

CVE-2024-46886
https://notcve.org/view.php?id=CVE-2024-46886
08 Oct 2024 — The web server of affected devices does not properly validate input that is used for a user redirection. This could allow an attacker to make the server redirect the legitimate user to an attacker-chosen URL. For a successful exploit, the legitimate user must actively click on an attacker-crafted link. • https://cert-portal.siemens.com/productcert/html/ssa-876787.html • CWE-601: URL Redirection to Untrusted Site ('Open Redirect') •

CVE-2022-38773
https://notcve.org/view.php?id=CVE-2022-38773
10 Jan 2023 — Affected devices do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot image of the device and execute arbitrary code. • https://cert-portal.siemens.com/productcert/pdf/ssa-482757.pdf • CWE-1326: Missing Immutable Root of Trust in Hardware •

CVE-2021-44693
https://notcve.org/view.php?id=CVE-2021-44693
13 Dec 2022 — Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-1284: Improper Validation of Specified Quantity in Input •

CVE-2021-44694
https://notcve.org/view.php?id=CVE-2021-44694
13 Dec 2022 — Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-20: Improper Input Validation CWE-1287: Improper Validation of Specified Type of Input •

CVE-2021-44695
https://notcve.org/view.php?id=CVE-2021-44695
13 Dec 2022 — Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-20: Improper Input Validation CWE-1286: Improper Validation of Syntactic Correctness of Input •

CVE-2021-40365
https://notcve.org/view.php?id=CVE-2021-40365
13 Dec 2022 — Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-20: Improper Input Validation •

CVE-2022-30694
https://notcve.org/view.php?id=CVE-2022-30694
08 Nov 2022 — The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. El endpoint de inicio de sesión /FormLogin en los servicios web afectados no aplica la verificación de origen adecuada. Esto podría permitir a atacantes remotos autenticados rastrear las actividades de otros usuarios mediante un ataque de Cross-Site Request Forgery (CSRF). • https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf • CWE-352: Cross-Site Request Forgery (CSRF) •

CVE-2021-42029
https://notcve.org/view.php?id=CVE-2021-42029
12 Apr 2022 — A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Port... • https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf • CWE-284: Improper Access Control •

CVE-2020-28397
https://notcve.org/view.php?id=CVE-2020-28397
10 Aug 2021 — A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS ... • https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf • CWE-863: Incorrect Authorization •