4 results (0.006 seconds)

CVSS: 9.8EPSS: 0%CPEs: 25EXPL: 0

A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known. Se ha identificado una vulnerabilidad en los dispositivos SIPROTEC 5 con variantes de CP200 (Todas las versiones anteriores a la versión V7.59), dispositivos SIPROTEC 5 con variantes de CP300 y CP100 (Todas las versiones anteriores a la versión V8.01), Siemens Power Meters Series 9410 (Todas las versiones anteriores a la versión V2.2.1), Siemens Power Meters Series 9810 (Todas las versiones). Un atacante no autenticado con acceso de red al dispositivo podría insertar un código arbitrario que se ejecuta antes de la verificación del firmware en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf • CWE-284: Improper Access Control •

CVSS: 7.5EPSS: 0%CPEs: 26EXPL: 0

A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system. Se ha identificado una vulnerabilidad en todos los demás tipos de dispositivos SIPROTEC 5 con variantes de CPU CP300 y CP100 y los respectivos módulos de comunicación Ethernet (todas las versiones), software de ingeniería DIGSI 5 (todas las versiones anteriores a la versión V7.90), tipos de dispositivos SIPROTEC 5 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 y 7VE85 y CPU con variantes CP300 y CP100 los respectivos módulos de comunicación Ethernet (todas las versiones anteriores a la versión V7.90), tipos de dispositivos SIPROTEC 5 7SS85 y 7KE85 (todas las versiones anteriores a la versión V8.01), tipos de dispositivos SIPROTEC 5 con variantes de CP200 y los respectivos módulos de comunicación Ethernet (todas las versiones). Un atacante remoto podría usar paquetes especialmente diseñados enviados al puerto 443/TCP para cargar, descargar o eliminar archivos en ciertas partes del sistema de archivos • https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf • CWE-434: Unrestricted Upload of File with Dangerous Type CWE-552: Files or Directories Accessible to External Parties •

CVSS: 7.5EPSS: 0%CPEs: 29EXPL: 0

A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition. Se ha identificado una vulnerabilidad en todos los demás tipos de dispositivos SIPROTEC 5 con variantes de CPU CP300 y CP100 y los respectivos módulos de comunicación Ethernet (todas las versiones), software de ingeniería DIGSI 5 (Todas las versiones anteriores a la versión V7.90), tipos de dispositivos SIPROTEC 5 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 y 7VE85 con variantes de CPU CP300 y CP100 los respectivos módulos de comunicación Ethernet (Todas las versiones anteriores a la versión V7.90), tipos de dispositivos SIPROTEC 5 7SS85 y 7KE85 (Todas las versiones anteriores a la versión V8.01), tipos de dispositivos SIPROTEC 5 con variantes CPU CP200 y los respectivos módulos de comunicación Ethernet (Todas las versiones anteriores a la versión V7.59), los relés SIPROTEC 5 con las variantes de CPU CP200 y los respectivos módulos de comunicación Ethernet (Todas las versiones anteriores a la versión V7.59). Los paquetes especialmente diseñados enviados al puerto 443/TCP podrían causar una condición de denegación de servicio • https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf • CWE-248: Uncaught Exception •

CVSS: 9.3EPSS: 0%CPEs: 11EXPL: 0

A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. • http://www.securityfocus.com/bid/105933 https://cert-portal.siemens.com/productcert/pdf/ssa-159860.pdf https://ics-cert.us-cert.gov/advisories/ICSA-18-317-01 • CWE-284: Improper Access Control •