1 results (0.001 seconds)

CVSS: 7.0EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 Safety V16 (todas las versiones &lt; V16 Update 7), SIMATIC STEP 7 Safety V17 (todas las versiones &lt; V17 Update 7), SIMATIC STEP 7 Safety V18 (todas las versiones &lt; V18 Update 2), SIMATIC STEP 7 V16 (todas las versiones &lt; V16 Update 7), SIMATIC STEP 7 V17 (todas las versiones &lt; V17 Update 7), SIMATIC STEP 7 V18 (todas las versiones &lt; V18 Update 2), SIMATIC WinCC Unified V16 (todas las versiones &lt; V16 Update 7), SIMATIC WinCC Unified V17 (todas las versiones &lt; V17 Update 7), SIMATIC WinCC Unified V18 (todas las versiones &lt; V18 Update 2), SIMATIC WinCC V16 (todas las versiones &lt; V16.7), SIMATIC WinCC V17 (todas las versiones &lt; V17.7), SIMATIC WinCC V18 (todas las versiones &lt; V18 Update 2), SIMOCODE ES V16 (todas las versiones &lt; V16 Update 7), SIMOCODE ES V17 (todas las versiones &lt; V17 Update 7), SIMOCODE ES V18 (todas las versiones &lt; V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (Todas las versiones), SIMOTION SCOUT TIA V5.4 SP3 (Todas las versiones), SIMOTION SCOUT TIA V5.5 SP1 (Todas las versiones), SINAMICS Startdrive V16 (Todas las versiones), SINAMICS Startdrive V17 (Todas las versiones), SINAMICS Startdrive V18 (todas las versiones), SIRIUS Safety ES V17 (todas las versiones &lt; V17 Update 7), SIRIUS Safety ES V18 (todas las versiones &lt; V18 Update 2), SIRIUS Soft Starter ES V17 (todas las versiones &lt; V17 Update 7), SIRIUS Soft Starter ES V18 (Todas las versiones &lt; V18 Actualización 2), Soft Starter ES V16 (Todas las versiones &lt; V16 Actualización 7), TIA Portal Cloud V3.0 (Todas las versiones &lt; V18 Actualización 2). Las aplicaciones afectadas no restringen adecuadamente .NET BinaryFormatter al deserializar perfiles de configuración de hardware. • https://cert-portal.siemens.com/productcert/html/ssa-779936.html • CWE-502: Deserialization of Untrusted Data •