5 results (0.002 seconds)

CVSS: 5.9EPSS: 0%CPEs: 205EXPL: 0

An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. • http://www.openwall.com/lists/oss-security/2021/03/27/1 http://www.openwall.com/lists/oss-security/2021/03/27/2 http://www.openwall.com/lists/oss-security/2021/03/28/3 http://www.openwall.com/lists/oss-security/2021/03/28/4 https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148 https://kb.pulse • CWE-476: NULL Pointer Dereference •

CVSS: 6.1EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. Se ha identificado una vulnerabilidad en SCALANCE S602 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S612 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S623 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S627-2M (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1). • https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf https://www.us-cert.gov/ics/advisories/icsa-20-042-10 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) •

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. Se ha identificado una vulnerabilidad en SCALANCE S602 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S612 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S623 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S627-2M (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1). Los paquetes especialmente diseñados enviados hacia el puerto 443/tcp de los dispositivos afectados podrían causar una condición de Denegación de Servicio del servidor web • https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf https://www.us-cert.gov/ics/advisories/icsa-20-042-10 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.8EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device. Se ha identificado una vulnerabilidad en SCALANCE S602 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S612 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S623 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S627-2M (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1). Los paquetes especialmente diseñados enviados hacia el puerto 443/tcp de los dispositivos afectados podrían causar una condición de Denegación de Servicio del servidor web. • https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf https://www.us-cert.gov/ics/advisories/icsa-20-042-10 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 5.4EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. • http://www.securityfocus.com/bid/105937 https://cert-portal.siemens.com/productcert/pdf/ssa-242982.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) •