10 results (0.004 seconds)

CVSS: 7.5EPSS: 0%CPEs: 26EXPL: 0

14 Apr 2020 — A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), ... • https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.8EPSS: 0%CPEs: 109EXPL: 0

11 Feb 2020 — Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker ... • https://cert-portal.siemens.com/productcert/html/ssa-780073.html • CWE-400: Uncontrolled Resource Consumption •

CVSS: 5.4EPSS: 0%CPEs: 16EXPL: 0

11 Feb 2020 — A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The devic... • https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf • CWE-693: Protection Mechanism Failure CWE-1021: Improper Restriction of Rendered UI Layers or Frames •

CVSS: 8.6EPSS: 0%CPEs: 14EXPL: 0

16 Jan 2020 — A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCAL... • https://cert-portal.siemens.com/productcert/pdf/ssa-443566.pdf • CWE-306: Missing Authentication for Critical Function •

CVSS: 7.5EPSS: 0%CPEs: 98EXPL: 0

10 Oct 2019 — A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU... • https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 5.5EPSS: 0%CPEs: 8EXPL: 0

12 Jun 2019 — A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. • https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf • CWE-257: Storing Passwords in a Recoverable Format CWE-522: Insufficiently Protected Credentials •

CVSS: 9.1EPSS: 0%CPEs: 10EXPL: 0

26 Mar 2019 — The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior. La barrera de monitorización de los productos afectados bloquea insuficientemente el reenvío de datos a través del puerto espejo hacia la red reflejada. Un atacante podría utilizar este comportamiento para ... • https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf • CWE-440: Expected Behavior Violation •

CVSS: 7.8EPSS: 0%CPEs: 9EXPL: 0

21 Jan 2015 — The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests. El servidor web en los switches SCALANCE X-300 con firmware anteriores a 4.0 y los switches SCALANCE X 408 con firmware anterior a 4.0 permite a atacantes remotos causar una denegación de servicio (reinicio) a través de peticiones HTTP mal formadas. • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 6.8EPSS: 0%CPEs: 9EXPL: 0

21 Jan 2015 — The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets. El servidor FTP Siemens en los switches SCALANCE X-300 con firmware anterior a 4.0 y los switches SCALANCE X 408 con firmware anterior a 4.0 permite a usuarios remotos autenticados causar una denegación de servicio (reinicio) a través de paquetes FTP modificados. • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf • CWE-20: Improper Input Validation •

CVSS: 9.8EPSS: 3%CPEs: 31EXPL: 0

18 Apr 2012 — Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL. Desbordamiento de búfer en el servidor web integrado en el conmutador ethernet industrial Siemens Scalance X X414-3E antes de v3.7.1, X308-2M antes de v3.7.2, X-300EEC antes de v3.... • http://osvdb.org/81032 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •