CVSS: 6.8EPSS: 0%CPEs: 180EXPL: 0

Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. Los dispositivos afectados no sanean correctamente los datos introducidos por un usuario al renderizar la interfaz web. Esto podría permitir a un atacante remoto autenticado con privilegios administrativos inyectar código y llevar a un XSS basado en el DOM • https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf • CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) •

CVSS: 7.5EPSS: 0%CPEs: 168EXPL: 0

Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. Los dispositivos afectados no manejan adecuadamente la renegociación de los parámetros SSL/TLS. Esto podría permitir a un atacante remoto no autenticado eludir la prevención de fuerza bruta de TCP y provocar una condición de denegación de servicio mientras dure el ataque • https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 9.1EPSS: 0%CPEs: 180EXPL: 0

Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Los dispositivos afectados no sanean correctamente un campo de entrada. Esto podría permitir a un atacante remoto autenticado con privilegios administrativos inyectar código o generar un shell de raíz del sistema • https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf • CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') •

CVSS: 7.8EPSS: 0%CPEs: 9EXPL: 0

The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests. El servidor web en los switches SCALANCE X-300 con firmware anteriores a 4.0 y los switches SCALANCE X 408 con firmware anterior a 4.0 permite a atacantes remotos causar una denegación de servicio (reinicio) a través de peticiones HTTP mal formadas. • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 6.8EPSS: 0%CPEs: 9EXPL: 0

The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets. El servidor FTP Siemens en los switches SCALANCE X-300 con firmware anterior a 4.0 y los switches SCALANCE X 408 con firmware anterior a 4.0 permite a usuarios remotos autenticados causar una denegación de servicio (reinicio) a través de paquetes FTP modificados. • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf • CWE-20: Improper Input Validation •