7 results (0.006 seconds)

CVSS: 6.8EPSS: 0%CPEs: 180EXPL: 0

Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. Los dispositivos afectados no sanean correctamente los datos introducidos por un usuario al renderizar la interfaz web. Esto podría permitir a un atacante remoto autenticado con privilegios administrativos inyectar código y llevar a un XSS basado en el DOM • https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf • CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) •

CVSS: 7.5EPSS: 0%CPEs: 168EXPL: 0

Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack. Los dispositivos afectados no manejan adecuadamente la renegociación de los parámetros SSL/TLS. Esto podría permitir a un atacante remoto no autenticado eludir la prevención de fuerza bruta de TCP y provocar una condición de denegación de servicio mientras dure el ataque • https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 9.1EPSS: 0%CPEs: 180EXPL: 0

Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Los dispositivos afectados no sanean correctamente un campo de entrada. Esto podría permitir a un atacante remoto autenticado con privilegios administrativos inyectar código o generar un shell de raíz del sistema • https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf • CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') •

CVSS: 7.5EPSS: 0%CPEs: 157EXPL: 0

Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autentificado desencadenar una condición de denegación de servicio. La vulnerabilidad puede activarse si se envía una gran cantidad de paquetes de restablecimiento de DCP al dispositivo • https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03 https://cert-portal.siemens.com/productcert/html/ssa-599968.html • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 8.8EPSS: 0%CPEs: 35EXPL: 0

A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active. Se ha identificado una vulnerabilidad en RUGGEDCOM RM1224 (Todas las versiones posteriores e incluyendo a V4.3 y anteriores a V6.4), SCALANCE M-800 (Todas las versiones posteriores e incluyendo a V4.3 y anteriores a V6.4), SCALANCE S615 (Todas las versiones posteriores e incluyendo a V4.3 y anteriores a V6.4), SCALANCE SC-600 Family (Todas las versiones posteriores e incluyendo a V2.0 y anteriores a V2.1.3), SCALANCE XB-200 (Todas las versiones anteriores a V4.1), SCALANCE XC-200 (Todas las versiones anteriores a V4.1), SCALANCE XF-200BA (Todas las versiones anteriores a V4.1), SCALANCE XM400 (Todas las versiones anteriores a V6.2), SCALANCE XP-200 (Todas las versiones anteriores a V4.1), SCALANCE XR-300WG (Todas las versiones anteriores a V4.1), SCALANCE XR500 (Todas las versiones anteriores a V6.2). Unos dispositivos afectados contienen una vulnerabilidad de desbordamiento de búfer en la región stack de la memoria en el manejo de frames STP BPDU que podría permitir a un atacante remoto desencadenar una condición de denegación de servicio o una ejecución de código potencialmente remoto. • https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •