3 results (0.002 seconds)

CVSS: 8.2EPSS: 0%CPEs: 12EXPL: 0

A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V16 (All versions), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC PCS 7 V9.1 (All versions), SIMATIC PDM V9.2 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC Unified PC Runtime (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. Se ha identificado una vulnerabilidad en: S7-PCT (todas las versiones), Security Configuration Tool (SCT) (todas las versiones), SIMATIC Automation Tool (todas las versiones), SIMATIC BATCH V9.1 (todas las versiones), SIMATIC NET PC Software (todas las versiones), SIMATIC PCS 7 V9.1 (todas las versiones), SIMATIC PDM V9.2 (todas las versiones), SIMATIC Route Control V9.1 (todas las versiones), SIMATIC STEP 7 V5 (todas las versiones), SIMATIC WinCC OA V3.17 ( Todas las versiones), SIMATIC WinCC OA V3.18 (todas las versiones &lt; V3.18 P025), SIMATIC WinCC OA V3.19 (todas las versiones &lt; V3.19 P010), SIMATIC WinCC Runtime Advanced (todas las versiones), SIMATIC WinCC Runtime Professional V16 (Todas las versiones), SIMATIC WinCC Runtime Professional V17 (todas las versiones), SIMATIC WinCC Runtime Professional V18 (todas las versiones), SIMATIC WinCC Runtime Professional V19 (todas las versiones), SIMATIC WinCC Unified PC Runtime (todas las versiones), SIMATIC WinCC V7.4 (Todas las versiones), SIMATIC WinCC V7.5 (Todas las versiones), SIMATIC WinCC V8.0 (Todas las versiones), SINAMICS Startdrive (Todas las versiones &lt; V19 SP1), SINUMERIK ONE virtual (Todas las versiones &lt; V6.23), Programación de PLC SINUMERIK Herramienta (todas las versiones), TIA Portal Cloud Connector (todas las versiones &lt; V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Portal de automatización integrado (TIA Portal) V17 (todas las versiones), Portal de automatización totalmente integrado (Portal TIA) V18 (todas las versiones), Portal de automatización totalmente integrado (TIA Portal) V19 (todas las versiones A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. • https://cert-portal.siemens.com/productcert/html/ssa-962515.html https://cert-portal.siemens.com/productcert/html/ssa-784301.html • CWE-125: Out-of-bounds Read •

CVSS: 6.5EPSS: 0%CPEs: 19EXPL: 0

A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover. Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones 4.2 HF1), SIMATIC Automation Tool (todas las versiones 3.0), SIMATIC NET PC-software (todas las versiones 14 SP1), SIMATIC PCS 7 Versión 8.1 (todas las versiones), SIMATIC PCS 7 Versión 8.2 (todas las versiones 8.2 SP1), SIMATIC STEP Versión 7 (TIA Portal) Versión 13 (todas las versiones 13 SP2), SIMATIC STEP Versión 7 (TIA Portal) Versión 14 (todas las versiones 14 SP1), SIMATIC STEP 7 Versión 5.x (todas las versiones 5.6), SIMATIC WinAC RTX 2010 SP2 (todas las versiones), SIMATIC WinAC RTX F 2010 SP2 (todas versiones), SIMATIC WinCC (TIA Portal) Versión 13 (todas las versiones 13 SP2), SIMATIC WinCC (TIA Portal) Versión 14 (todas las versiones 14 SP1), SIMATIC WinCC Versión 7.2 y anteriores (todos versiones), SIMATIC WinCC Versión 7.3 (todas las versiones 7.3 actualización 15), SIMATIC WinCC Versión 7.4 (todas las versiones 7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (todas las versiones anteriores a flexible 2008 SP5), SINAUT ST7CC (todas las versiones instaladas en conjunto con SIMATIC WinCC Versión 7.3 actualización 15), SINEMA Server (todas las versiones 14), SINUMERIK 808D Programming Tool (todas las versiones 4.7 SP4 HF2), SMART PC Access (todas las versiones 2.3), STEP 7 - Micro/WIN SMART (todas las versiones 2.3), Security Configuration Tool (SCT) (todas las versiones 5.0). Los paquetes de difusión PROFINET DCP especialmente creados enviados a los productos afectados en un segmento Ethernet local (Layer 2) podrían causar una condición de denegación de servicio de algunos servicios. • https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf https://www.securityfocus.com/bid/98366 • CWE-20: Improper Input Validation •

CVSS: 6.9EPSS: 0%CPEs: 27EXPL: 0

A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent). Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones anteriores a V4.2 HF1), SIMATIC IT Production Suite (todas las versiones anteriores a V7.0 SP1 HFX 2), SIMATIC NET PC-Software (Todas las versiones anteriores a V14), SIMATIC PCS 7 versión V7.1 (Todas las versiones), SIMATIC PCS 7 versión V8.0 (Todas las versiones), SIMATIC PCS 7 versión V8.1 (Todas las versiones),SIMATIC PCS 7 versión V8.2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC STEP 7 (TIA Portal) versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC STEP 7 versiones V5.X (Todas las versiones anteriores a V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (Todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) Professional versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) Professional versión V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC Runtime Professional versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC Runtime Professional versión V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC versión V7.0 SP2 y anteriores (Todas las versiones anteriores a V7.0 SP2 Upd 12), SIMATIC WinCC versión V7.0 SP3 (Todas las versiones anteriores a V7.0 SP3 Upd 8), SIMATIC WinCC versión V7.2 (Todas las versiones anteriores a V7.2 Upd 14), SIMATIC WinCC versión V7.3 (Todas las versiones anteriores a V7.3 Upd 11), SIMATIC WinCC versión V7.4 (Todas las versiones anteriores a V7.4 SP1), SIMIT versión V9.0 (Todas las versiones anteriores a V9.0 SP1), SINEMA Remote Connect Client (Todas las versiones anteriores a V1.0 SP3), SINEMA Server (Todas las versiones anteriores a V13 SP2), SOFTNET Security Client versión V5.0 (Todas las versiones), Security Configuration Tool (SCT) (Todas las versiones anteriores a V4.3 HF1), TeleControl Server Basic (Todas las versiones anteriores a V3.0 SP2), WinAC RTX 2010 SP2 (Todas las versiones), WinAC RTX F 2010 SP2 (Todas las versiones). Las rutas (path) de servicio sin comillas podrían permitir que los usuarios locales del sistema operativo Microsoft Windows aumenten sus privilegios si los productos afectados no están instalados en su ruta (path) de acceso predeterminada ("C:\Program Files\*" o el equivalente localizado). • http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html http://www.securityfocus.com/bid/94158 https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 • CWE-254: 7PK - Security Features CWE-284: Improper Access Control •